Interpolation of 3D Magnetic Resonance Data
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F11%3APU91940" target="_blank" >RIV/00216305:26220/11:PU91940 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68081731:_____/11:00367355
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Interpolation of 3D Magnetic Resonance Data
Popis výsledku v původním jazyce
This article deals with three-dimensional reconstruction methods of nuclear magnetic resonance images. The testing images were observed by tomography with basic magnetic field of 4.7T at the Institute of Scientific Instruments (Academy of Sciences of theCzech Republic). The 20 slices of the test phantom were acquired. Two methods were found with the aim of getting utmost information about the shape of the testing phantom. One possible way is to increase the count of the sensed slices, but it implies decreasing of the signal to noise ratio. The second approach is finding the compromise between the effective count of slices and the following interpolation of other slices between the sensed ones. The both approaches were compared. Only 10 slices were used to compute the in-between others. It is better to use this approach because the computed slices can be compared with the real slices obtained by MR tomography. The re- sults are described in the article. The images were interpolated in
Název v anglickém jazyce
Interpolation of 3D Magnetic Resonance Data
Popis výsledku anglicky
This article deals with three-dimensional reconstruction methods of nuclear magnetic resonance images. The testing images were observed by tomography with basic magnetic field of 4.7T at the Institute of Scientific Instruments (Academy of Sciences of theCzech Republic). The 20 slices of the test phantom were acquired. Two methods were found with the aim of getting utmost information about the shape of the testing phantom. One possible way is to increase the count of the sensed slices, but it implies decreasing of the signal to noise ratio. The second approach is finding the compromise between the effective count of slices and the following interpolation of other slices between the sensed ones. The both approaches were compared. Only 10 slices were used to compute the in-between others. It is better to use this approach because the computed slices can be compared with the real slices obtained by MR tomography. The re- sults are described in the article. The images were interpolated in
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
PIERS ONLINE
ISSN
1931-7360
e-ISSN
—
Svazek periodika
7
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—