Noise and Electro-Ultrasonic Spectroscopy of Conducting Polymer Thick Films
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F11%3APU95273" target="_blank" >RIV/00216305:26220/11:PU95273 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Noise and Electro-Ultrasonic Spectroscopy of Conducting Polymer Thick Films
Popis výsledku v původním jazyce
Thick conducting films based on conducting polymer are characterized by DC conductivity and noise in temperature range 10 to 300 K. Conducting polymers could be used e.g. for the top electrode (cathode) in the solid tantalum or niobium capacitors. On theconducting polymer layer the top layer of carbon/graphite and/or silver polymer based pastes is applied in the capacitor technology. Our samples structure consists of conducting polymer layers with semiconductor conductivity applied on the alumina substrate of the size 50 x 4 mm2. Contact electrodes are prepared either from two layers - carbon/graphite paste (lower one) and silver paste (upper one), or by silver paste layer only. We are measuring DC conductivity of the structures, which is of the orderof 1 mS at the room temperature and decreases with decreasing temperature for both types of contact technologies. For the evaluation of the contact technology two testing methods are proposed. The first is the measurement of the potentia
Název v anglickém jazyce
Noise and Electro-Ultrasonic Spectroscopy of Conducting Polymer Thick Films
Popis výsledku anglicky
Thick conducting films based on conducting polymer are characterized by DC conductivity and noise in temperature range 10 to 300 K. Conducting polymers could be used e.g. for the top electrode (cathode) in the solid tantalum or niobium capacitors. On theconducting polymer layer the top layer of carbon/graphite and/or silver polymer based pastes is applied in the capacitor technology. Our samples structure consists of conducting polymer layers with semiconductor conductivity applied on the alumina substrate of the size 50 x 4 mm2. Contact electrodes are prepared either from two layers - carbon/graphite paste (lower one) and silver paste (upper one), or by silver paste layer only. We are measuring DC conductivity of the structures, which is of the orderof 1 mS at the room temperature and decreases with decreasing temperature for both types of contact technologies. For the evaluation of the contact technology two testing methods are proposed. The first is the measurement of the potentia
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IMAPS ? IEEE CPMT Poland Conference
ISBN
978-83-932464-0-3
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
59-66
Název nakladatele
IMAPS - CPMT IEEE Poland
Místo vydání
Gdansk, Poland
Místo konání akce
Gdansk
Datum konání akce
21. 11. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—