The Method of Correction the B1 Errors in MagnetizationTransfer Ratio MTR
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F12%3APU99655" target="_blank" >RIV/00216305:26220/12:PU99655 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Method of Correction the B1 Errors in MagnetizationTransfer Ratio MTR
Popis výsledku v původním jazyce
The meaning of MRI is based on the concept of the magnetic sum vectors, Mz and Mxy, which related with resonant frequency RF, where the physics idea in MRI is influencedby the external magnetic field B0 on the nuclear magnetic moment vector of proton inhydrogen,but the radio-frequency RF field B1 errors is based on magnetization transfer ratio MTR measurements, and radio frequency RF no uniformity, so it is important to correctthe B1 errors inmagnetization transfer ratio measurements, so this paper will discuss about the methods of correction at large volumetric radio frequency RF field, and this correction based on the double-angle method DAM. Two factors are related with B1 field mapping techniques, the first one is double angle method DAM, and theother one is the fast spin-echo FSE, where the value of magnetization transferratio depends on the amplitude of the magnetization transfer MT pulse[1]. The aim from this paper to explain the B1 errors in the MTR and the method of correcti
Název v anglickém jazyce
The Method of Correction the B1 Errors in MagnetizationTransfer Ratio MTR
Popis výsledku anglicky
The meaning of MRI is based on the concept of the magnetic sum vectors, Mz and Mxy, which related with resonant frequency RF, where the physics idea in MRI is influencedby the external magnetic field B0 on the nuclear magnetic moment vector of proton inhydrogen,but the radio-frequency RF field B1 errors is based on magnetization transfer ratio MTR measurements, and radio frequency RF no uniformity, so it is important to correctthe B1 errors inmagnetization transfer ratio measurements, so this paper will discuss about the methods of correction at large volumetric radio frequency RF field, and this correction based on the double-angle method DAM. Two factors are related with B1 field mapping techniques, the first one is double angle method DAM, and theother one is the fast spin-echo FSE, where the value of magnetization transferratio depends on the amplitude of the magnetization transfer MT pulse[1]. The aim from this paper to explain the B1 errors in the MTR and the method of correcti
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F09%2F0314" target="_blank" >GA102/09/0314: Studium vlastností metamateriálů a mikrovlnných struktur s využitím šumové spektroskopie a magnetické rezonance</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
PIERS 2012 in Moscow Proceedings
ISBN
978-1-934142-22-6
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
Neuveden
Místo vydání
Moscow
Místo konání akce
Moscow
Datum konání akce
19. 8. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce