4D dynamic contrast enhanced CT data registration using optical flow
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F14%3APU109129" target="_blank" >RIV/00216305:26220/14:PU109129 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.feec.vutbr.cz/EEICT/wp-content/uploads/2014/04/2014-sbornik-phd.pdf" target="_blank" >http://www.feec.vutbr.cz/EEICT/wp-content/uploads/2014/04/2014-sbornik-phd.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
4D dynamic contrast enhanced CT data registration using optical flow
Popis výsledku v původním jazyce
This paper deals with 4D (3D + time) registration method based on optical flow. The main goal is to obtain the velocity field, which is used to correction of displacement in the thoracic data. The one of the most widely used optical flow method publishedby Horn and Schunck, is utilized in this paper. The proposed method is based on H-S scheme, which is extended by pyramidal and multi-level approach. This allows estimation a larger displacements and this algorithm is thus more robust. Moreover the optical flow method was extended for three-dimension images that develops in time. The performance of proposed algorithm was applied on POPI model, the public model of lung data, which was deformed by synthetic velocity field.
Název v anglickém jazyce
4D dynamic contrast enhanced CT data registration using optical flow
Popis výsledku anglicky
This paper deals with 4D (3D + time) registration method based on optical flow. The main goal is to obtain the velocity field, which is used to correction of displacement in the thoracic data. The one of the most widely used optical flow method publishedby Horn and Schunck, is utilized in this paper. The proposed method is based on H-S scheme, which is extended by pyramidal and multi-level approach. This allows estimation a larger displacements and this algorithm is thus more robust. Moreover the optical flow method was extended for three-dimension images that develops in time. The performance of proposed algorithm was applied on POPI model, the public model of lung data, which was deformed by synthetic velocity field.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 20th Conference STUDENT EEICT 2014 Volume 3
ISBN
978-80-214-4924-4
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
222-226
Název nakladatele
LITERA
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
24. 4. 2014
Typ akce podle státní příslušnosti
CST - Celostátní akce