Automatic Exudates Detection in Fundus Image using Intensity Thresholding and Morphology
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F15%3APU115944" target="_blank" >RIV/00216305:26220/15:PU115944 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/7382452" target="_blank" >https://ieeexplore.ieee.org/document/7382452</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ICUMT.2015.7382452" target="_blank" >10.1109/ICUMT.2015.7382452</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Automatic Exudates Detection in Fundus Image using Intensity Thresholding and Morphology
Popis výsledku v původním jazyce
Diabetic retinopathy (DR) is a leading cause of blindness in diabetic patients. Exudates are one of the most common earliest signs of diabetic retinopathy. Automatic and accurate detection of exudates in fundus images is an important step in early diagnosis of DR. In the proposed method detection of exudates, two independent approaches based on intensity thresholding and morphological processing are strategically combined to detect any small exudates present while removing all possible types of false positives. This strategic combination removes the noise sources from blood vessels and reflections during image capture making the detection of exudates accurate. Experimental results indicate that the proposed method has good accuracy in exudates detection without compromising the computational time and hence can be considered for screening purpose of DR.
Název v anglickém jazyce
Automatic Exudates Detection in Fundus Image using Intensity Thresholding and Morphology
Popis výsledku anglicky
Diabetic retinopathy (DR) is a leading cause of blindness in diabetic patients. Exudates are one of the most common earliest signs of diabetic retinopathy. Automatic and accurate detection of exudates in fundus images is an important step in early diagnosis of DR. In the proposed method detection of exudates, two independent approaches based on intensity thresholding and morphological processing are strategically combined to detect any small exudates present while removing all possible types of false positives. This strategic combination removes the noise sources from blood vessels and reflections during image capture making the detection of exudates accurate. Experimental results indicate that the proposed method has good accuracy in exudates detection without compromising the computational time and hence can be considered for screening purpose of DR.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1401" target="_blank" >LO1401: Interdisciplinární výzkum bezdrátových technologií</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2015 7th International Congress on Ultra Modern Telecommunications and Control Systems and Workshops (ICUMT)
ISBN
978-1-4673-9282-2
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
330-334
Název nakladatele
Neuveden
Místo vydání
Brno, Czech Republic
Místo konání akce
Brno
Datum konání akce
6. 10. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000380551300058