Dynamic Flux Balance Control of a Phase-shifted Full Bridge
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F23%3APU149526" target="_blank" >RIV/00216305:26220/23:PU149526 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/xpl/conhome/10273860/proceeding" target="_blank" >https://ieeexplore.ieee.org/xpl/conhome/10273860/proceeding</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dynamic Flux Balance Control of a Phase-shifted Full Bridge
Popis výsledku v původním jazyce
A standard method for controlling a phase-shifted full bridge converter is the voltage-mode PWM. In this case the switching signals are based on an internal ramp generator and the control voltage affects the phase shift directly. With such control method it is not guaranteed that the transformer flux density remains within specified boundaries for both static and dynamic (transient) control behavior as the positive and negative pulse widths are not linked in any way. This paper presents an alternative approach which uses a reconstructed flux signal as the basis for generating the control signals, assuring the flux stays within the control boundaries even for very fast transients, with superimposed interference etc. Also, it requires no internal ramp generator as the reconstructed flux waveform itself is used as the reference ramp. Such control allows for construction of high-quality converters with a very fast dynamic response, finding use in welders, plasma arc supplies etc.
Název v anglickém jazyce
Dynamic Flux Balance Control of a Phase-shifted Full Bridge
Popis výsledku anglicky
A standard method for controlling a phase-shifted full bridge converter is the voltage-mode PWM. In this case the switching signals are based on an internal ramp generator and the control voltage affects the phase shift directly. With such control method it is not guaranteed that the transformer flux density remains within specified boundaries for both static and dynamic (transient) control behavior as the positive and negative pulse widths are not linked in any way. This paper presents an alternative approach which uses a reconstructed flux signal as the basis for generating the control signals, assuring the flux stays within the control boundaries even for very fast transients, with superimposed interference etc. Also, it requires no internal ramp generator as the reconstructed flux waveform itself is used as the reference ramp. Such control allows for construction of high-quality converters with a very fast dynamic response, finding use in welders, plasma arc supplies etc.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_013%2F0001638" target="_blank" >EF16_013/0001638: Výkonové laboratoře CVVOZE - modernizace výzkumné infrastruktury</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2023 International Conference on Electrical Drives and Power Electronics (EDPE)
ISBN
979-8-3503-2275-0
ISSN
2770-7652
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1-5
Název nakladatele
Technical University of Košice, Letná 9, 042 00 Košice
Místo vydání
Nový Smokovec, Slovakia
Místo konání akce
Nový Smokovec
Datum konání akce
25. 9. 2023
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—