Studium možnosti separace thaumatinu kapilární elektroforézou
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F03%3APU49867" target="_blank" >RIV/00216305:26310/03:PU49867 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Exploration on the separability of thaumatin by capillary electrophoresis
Popis výsledku v původním jazyce
Electrophoretic behaviour of highly basic protein thaumatin was explored in strongly acid (pH 2) and mildly acid (pH 4.5) separation systems using both bare and coated fused silica capillaries. Separation selectivity for thaumatin I, thaumatin II and forother sample constituents was nor sufficient for their baseline separation at pH 2 with uncoated capillary because of separation efficiency, which was markedly lower than common in electrophoretic separations of proteins. Separation selectivity higher uup to one order of magnitude has been reached at pH 4.5. Pronounced asymmetry of zones, which deteriorated resolution at this pH, was effectively suppressed by the coating of the capillary wall with a polymer. Electrochromatographic separation systems based on capillaries coated with the layer of either cationic or hydrophilic uncharged polymer appear to be promising for the development of methods for thaumatin analysis.
Název v anglickém jazyce
Exploration on the separability of thaumatin by capillary electrophoresis
Popis výsledku anglicky
Electrophoretic behaviour of highly basic protein thaumatin was explored in strongly acid (pH 2) and mildly acid (pH 4.5) separation systems using both bare and coated fused silica capillaries. Separation selectivity for thaumatin I, thaumatin II and forother sample constituents was nor sufficient for their baseline separation at pH 2 with uncoated capillary because of separation efficiency, which was markedly lower than common in electrophoretic separations of proteins. Separation selectivity higher uup to one order of magnitude has been reached at pH 4.5. Pronounced asymmetry of zones, which deteriorated resolution at this pH, was effectively suppressed by the coating of the capillary wall with a polymer. Electrochromatographic separation systems based on capillaries coated with the layer of either cationic or hydrophilic uncharged polymer appear to be promising for the development of methods for thaumatin analysis.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Separation Science
ISSN
1615-9306
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
7
Strana od-do
727-733
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—