Studium adsorpce proteinů v polyethyleniminem koutovaných kapilárách v kapilární zónové elektroforéze
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F05%3A00025070" target="_blank" >RIV/00216224:14310/05:00025070 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Studies of proteins adsorption in polyethyleneimine coated capillaries in capillary zone electrophoresis
Popis výsledku v původním jazyce
The magnitude and the direction of electroosmotic flow (EOF) has fundamental influence to separation in capillary zone electrophoresis. Adsorption of proteins on the negative charged silica surface of uncoated capillaries can lead to analyte loss and toirreproducibility of analyses. Therefore, in biomolecules analyses, the inner surface modification of fused-silica capillaries is recommended. One of the used coating is polyethyleneimine (PEI): as a polycationic polymer it creates positively charged covalent coating on the capillary inner wall and hence minimizes the adsorption of basic proteins at acidic pH and maintains the electroosmotic flow stable [1]. In this work, the properties of PEI coated capillaries with respect to different background electrolytes are described. The changes of inner surface of the capillary were followed by electroosmotic flow measurement [2]. Several buffers commonly used in electrophoretic separations of proteins (MES, acetate, borate) were tested, but t
Název v anglickém jazyce
Studies of proteins adsorption in polyethyleneimine coated capillaries in capillary zone electrophoresis
Popis výsledku anglicky
The magnitude and the direction of electroosmotic flow (EOF) has fundamental influence to separation in capillary zone electrophoresis. Adsorption of proteins on the negative charged silica surface of uncoated capillaries can lead to analyte loss and toirreproducibility of analyses. Therefore, in biomolecules analyses, the inner surface modification of fused-silica capillaries is recommended. One of the used coating is polyethyleneimine (PEI): as a polycationic polymer it creates positively charged covalent coating on the capillary inner wall and hence minimizes the adsorption of basic proteins at acidic pH and maintains the electroosmotic flow stable [1]. In this work, the properties of PEI coated capillaries with respect to different background electrolytes are described. The changes of inner surface of the capillary were followed by electroosmotic flow measurement [2]. Several buffers commonly used in electrophoretic separations of proteins (MES, acetate, borate) were tested, but t
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA305%2F03%2F1100" target="_blank" >GA305/03/1100: Syntéza a studium neuroprotektivních peptidů odvozených od humaninu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
11th International Symposium on Separation Sciences ISSS 2005. Book of Abstracts.
ISBN
80-7194-771-7
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
—
Název nakladatele
Univerzita Pardubice
Místo vydání
Pardubice
Místo konání akce
Pardubice
Datum konání akce
1. 1. 2005
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—