Development and application of SPE/CZE method for detection and determination of selected non-steroidal anti-inflammatory drugs in wastewater
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F12%3APU97412" target="_blank" >RIV/00216305:26310/12:PU97412 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68081715:_____/12:00391756
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development and application of SPE/CZE method for detection and determination of selected non-steroidal anti-inflammatory drugs in wastewater
Popis výsledku v původním jazyce
This study is focused on the development and application of reliable analytical method for detection and determination of 6 selected acidic drugs from the group on non-steroidal anti-inflammatory drugs: acetaminophen (paracetamol), ibuprofen, naproxen, ketoprofen, diclofenac and salicylic acid. Applied method is based on solid phase extraction (SPE) and final analysis by capillary zone electrophoresis with detector of diode array (CZE-DAD). SPE/CZE method is presented as a method applicable in the fieldof environmental analysis and monitoring of aquatic ecosystems. The method was successfully applied for the determination of selected drugs in wastewaters from the influent and effluent of wastewater treatment plant (WWTP) in Brno-Modřice, Czech Republic. Limits of detection were ranged from 0.46 to 1.28 ug/L depending on specific compound. Levels of concentrations of selected drugs were ranged from 0.61 to 42.80 ug/L in the influent and from 0.47 to 6.46 ug/L in the effluent of the WWT
Název v anglickém jazyce
Development and application of SPE/CZE method for detection and determination of selected non-steroidal anti-inflammatory drugs in wastewater
Popis výsledku anglicky
This study is focused on the development and application of reliable analytical method for detection and determination of 6 selected acidic drugs from the group on non-steroidal anti-inflammatory drugs: acetaminophen (paracetamol), ibuprofen, naproxen, ketoprofen, diclofenac and salicylic acid. Applied method is based on solid phase extraction (SPE) and final analysis by capillary zone electrophoresis with detector of diode array (CZE-DAD). SPE/CZE method is presented as a method applicable in the fieldof environmental analysis and monitoring of aquatic ecosystems. The method was successfully applied for the determination of selected drugs in wastewaters from the influent and effluent of wastewater treatment plant (WWTP) in Brno-Modřice, Czech Republic. Limits of detection were ranged from 0.46 to 1.28 ug/L depending on specific compound. Levels of concentrations of selected drugs were ranged from 0.61 to 42.80 ug/L in the influent and from 0.47 to 6.46 ug/L in the effluent of the WWT
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Fresenius Environmental Bulletin
ISSN
1018-4619
e-ISSN
—
Svazek periodika
21
Číslo periodika v rámci svazku
11a
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
3312-3317
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—