Simple Liquid Chromatography system for Low Flow Rate Gradient Separations
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F14%3APU111548" target="_blank" >RIV/00216305:26310/14:PU111548 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68081715:_____/13:00437647
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Simple Liquid Chromatography system for Low Flow Rate Gradient Separations
Popis výsledku v původním jazyce
In this contribution we describe simple approach to the splitless micro-flow liquid chromatograph construction and we demonstrate the functionality of the proposed system. Separation system consists of the programmable syringe pump equipped with the strain gauge force transducer and the high pressure syringe connected to the selector valve via long capillary where mobile phase gradient is generated and stored. Operation of the system is controlled by LabVIEW development environment. Mobile phase gradient is created by successive sucking of defined volumes of four solutions with gradually changing composition into the capillary. Available linear gradients of volumes from 5 to 50 ?l traced by uracil are presented. Depending on the selected mode, the system is quickly pressurized and the syringe pump delivers the mobile phase at the constant flow rate or the LabVIEW application drives the syringe pump speed according to the signal from the force transducer and holds the pressure constant.
Název v anglickém jazyce
Simple Liquid Chromatography system for Low Flow Rate Gradient Separations
Popis výsledku anglicky
In this contribution we describe simple approach to the splitless micro-flow liquid chromatograph construction and we demonstrate the functionality of the proposed system. Separation system consists of the programmable syringe pump equipped with the strain gauge force transducer and the high pressure syringe connected to the selector valve via long capillary where mobile phase gradient is generated and stored. Operation of the system is controlled by LabVIEW development environment. Mobile phase gradient is created by successive sucking of defined volumes of four solutions with gradually changing composition into the capillary. Available linear gradients of volumes from 5 to 50 ?l traced by uracil are presented. Depending on the selected mode, the system is quickly pressurized and the syringe pump delivers the mobile phase at the constant flow rate or the LabVIEW application drives the syringe pump speed according to the signal from the force transducer and holds the pressure constant.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VG20112015021" target="_blank" >VG20112015021: Vývoj instrumentálních metodických postupů rychlé detekce a identifikace biologických agens v reálných vzorcích</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Studentská odborná konference Chemie je život 2014 Sborník příspěvků
ISBN
978-80-214-5078-3
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
416-421
Název nakladatele
Vysoké učení technické v Brně, Fakulta chemická, Purkyňova 464/118, 612 00 Brno
Místo vydání
Brno
Místo konání akce
Purkyňova 118, 612 00 Brno
Datum konání akce
4. 12. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—