ASSAY OF NATURAL ANTIOXIDANTS POTENCY USING PIPETING ROBOT AND SPECTROPHOTOMETRY
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F12%3APU126850" target="_blank" >RIV/00216305:26620/12:PU126850 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
ASSAY OF NATURAL ANTIOXIDANTS POTENCY USING PIPETING ROBOT AND SPECTROPHOTOMETRY
Popis výsledku v původním jazyce
This work deals with the comparing antioxidant aktivity standards gallic acid, ferulic acid, qiercitrine and rutine with oxidative status model cell lines. The assay was carried out by methods DPPH, ABTS, DMPD, FRAP and free radicals. Antioxidant activity was determined individual standards in relation to time, concentration and temperature, compared the characteristics of each set of radicals and their antioxidant capacity. We decided to introduce fully automated assay of antioxidants using not only automated sample measurement but also processing of samples and application of reagents. Automated pipetting system epMotion 5075 and the automated spectrophotometer BS 400 were chosen for the assay purposes. All of the tested methods were found suitable for implementation in the automated assay. Owing to the capacity of the method, approximately 240 samples per hour (one sample per 15 seconds) can be assayed using the automated protocol.
Název v anglickém jazyce
ASSAY OF NATURAL ANTIOXIDANTS POTENCY USING PIPETING ROBOT AND SPECTROPHOTOMETRY
Popis výsledku anglicky
This work deals with the comparing antioxidant aktivity standards gallic acid, ferulic acid, qiercitrine and rutine with oxidative status model cell lines. The assay was carried out by methods DPPH, ABTS, DMPD, FRAP and free radicals. Antioxidant activity was determined individual standards in relation to time, concentration and temperature, compared the characteristics of each set of radicals and their antioxidant capacity. We decided to introduce fully automated assay of antioxidants using not only automated sample measurement but also processing of samples and application of reagents. Automated pipetting system epMotion 5075 and the automated spectrophotometer BS 400 were chosen for the assay purposes. All of the tested methods were found suitable for implementation in the automated assay. Owing to the capacity of the method, approximately 240 samples per hour (one sample per 15 seconds) can be assayed using the automated protocol.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0072" target="_blank" >ED2.1.00/03.0072: Centrum senzorických, informačních a komunikačních systémů (SIX)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
MENDELNET 2012
ISBN
978-80-7375-836-3
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
1166-1173
Název nakladatele
Neuveden
Místo vydání
Neuveden
Místo konání akce
Mendel Univ, Fac Agron, Brno
Datum konání akce
21. 11. 2012
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
000366461200136