Rapid Characterization of Biomolecules’ Thermal Stability in Segmented Flow-Through Optofluidic Microsystem
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F20%3APU135888" target="_blank" >RIV/00216305:26620/20:PU135888 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.nature.com/articles/s41598-020-63620-5" target="_blank" >https://www.nature.com/articles/s41598-020-63620-5</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1038/s41598-020-63620-5" target="_blank" >10.1038/s41598-020-63620-5</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Rapid Characterization of Biomolecules’ Thermal Stability in Segmented Flow-Through Optofluidic Microsystem
Popis výsledku v původním jazyce
Optofluidic devices combining optics and microfluidics have recently attracted attention for biomolecular analysis due to their high detection sensitivity. Here, we show a silicon chip with tubular microchannels buried inside the substrate featuring temperature gradient (∇T) along the microchannel. We set up an optical fluorescence system consisting of a power-modulated laser light source of 470 nm coupled to the microchannel serving as a light guide via optical fiber. Fluorescence was detected on the other side of the microchannel using a photomultiplier tube connected to an optical fiber via a fluorescein isothiocyanate filter. The PMT output was connected to a lock-in amplifier for signal processing. We performed a melting curve analysis of a short dsDNA – SYBR Green I complex with a known melting temperature (TM) in a flow-through configuration without gradient to verify the functionality of proposed detection system. We then used the segmented flow configuration and measured the fluorescence amplitude of a droplet exposed to ∇T of ≈ 2.31°C mm-1, determining the heat transfer time as ≈ 563 ms. The proposed platform can be used as a fast and cost-effective system for performing either MCA of dsDNAs or for measuring protein unfolding for drug-screening applications.
Název v anglickém jazyce
Rapid Characterization of Biomolecules’ Thermal Stability in Segmented Flow-Through Optofluidic Microsystem
Popis výsledku anglicky
Optofluidic devices combining optics and microfluidics have recently attracted attention for biomolecular analysis due to their high detection sensitivity. Here, we show a silicon chip with tubular microchannels buried inside the substrate featuring temperature gradient (∇T) along the microchannel. We set up an optical fluorescence system consisting of a power-modulated laser light source of 470 nm coupled to the microchannel serving as a light guide via optical fiber. Fluorescence was detected on the other side of the microchannel using a photomultiplier tube connected to an optical fiber via a fluorescein isothiocyanate filter. The PMT output was connected to a lock-in amplifier for signal processing. We performed a melting curve analysis of a short dsDNA – SYBR Green I complex with a known melting temperature (TM) in a flow-through configuration without gradient to verify the functionality of proposed detection system. We then used the segmented flow configuration and measured the fluorescence amplitude of a droplet exposed to ∇T of ≈ 2.31°C mm-1, determining the heat transfer time as ≈ 563 ms. The proposed platform can be used as a fast and cost-effective system for performing either MCA of dsDNAs or for measuring protein unfolding for drug-screening applications.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
21002 - Nano-processes (applications on nano-scale); (biomaterials to be 2.9)
Návaznosti výsledku
Projekt
<a href="/cs/project/GA16-11140S" target="_blank" >GA16-11140S: Na mikrofludice založená velmi rychlá diferenční fluometrie pro výzkum léků (µDSF)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scientific Reports
ISSN
2045-2322
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
1-9
Kód UT WoS článku
000559766900002
EID výsledku v databázi Scopus
2-s2.0-85083850663