Droplet-based differential microcalorimeter for real-time energy balance monitoring
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F20%3APU136483" target="_blank" >RIV/00216305:26620/20:PU136483 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60461373:22310/20:43920482
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0925400520303154" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0925400520303154</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.snb.2020.127967" target="_blank" >10.1016/j.snb.2020.127967</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Droplet-based differential microcalorimeter for real-time energy balance monitoring
Popis výsledku v původním jazyce
Microcalorimeters have been widely used for characterizing molecular interactions in physical, chemical and biological research. Here, we report on a droplet-based micromachined calorimeter for real-time energy balance monitoring. The microcalorimeter was fabricated by a single lithography process and wafer dicing using glass substrate with a diameter and a thickness of approximate to 100 mm and approximate to 100 mu m, respectively. The sample with volume of approximate to 0.5 mu L was placed on the microcalorimeter and covered with mineral oil to avoid evaporation. The microcalorimeter was operated in differential mode having the temperature and power resolution of approximate to 148 mu k and approximate to 42 nW, respectively. With this system, we monitored the energy balance of H2O2 decomposition catalyzed by few self-propelled Pt microrobots. Such a simple microcalorimeter has tremendous potential for chemical and biological research such as monitoring the energy balance of living cells or microorganisms and correlating the energy changes with their activities and status.
Název v anglickém jazyce
Droplet-based differential microcalorimeter for real-time energy balance monitoring
Popis výsledku anglicky
Microcalorimeters have been widely used for characterizing molecular interactions in physical, chemical and biological research. Here, we report on a droplet-based micromachined calorimeter for real-time energy balance monitoring. The microcalorimeter was fabricated by a single lithography process and wafer dicing using glass substrate with a diameter and a thickness of approximate to 100 mm and approximate to 100 mu m, respectively. The sample with volume of approximate to 0.5 mu L was placed on the microcalorimeter and covered with mineral oil to avoid evaporation. The microcalorimeter was operated in differential mode having the temperature and power resolution of approximate to 148 mu k and approximate to 42 nW, respectively. With this system, we monitored the energy balance of H2O2 decomposition catalyzed by few self-propelled Pt microrobots. Such a simple microcalorimeter has tremendous potential for chemical and biological research such as monitoring the energy balance of living cells or microorganisms and correlating the energy changes with their activities and status.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors and Actuators B: Chemical
ISSN
0925-4005
e-ISSN
—
Svazek periodika
312
Číslo periodika v rámci svazku
NA
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
7
Strana od-do
1-7
Kód UT WoS článku
000526109000019
EID výsledku v databázi Scopus
—