On quantitativeness of diffraction-limited quantitative phase imaging
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F24%3APU155954" target="_blank" >RIV/00216305:26620/24:PU155954 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15310/24:73627004
Výsledek na webu
<a href="https://pubs.aip.org/aip/app/article/9/12/126111/3325120/On-quantitativeness-of-diffraction-limited" target="_blank" >https://pubs.aip.org/aip/app/article/9/12/126111/3325120/On-quantitativeness-of-diffraction-limited</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/5.0232405" target="_blank" >10.1063/5.0232405</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
On quantitativeness of diffraction-limited quantitative phase imaging
Popis výsledku v původním jazyce
Quantitative phase imaging (QPI) has advanced by accurately quantifying phase shifts caused by weakly absorbing biological and artificial structures. Despite extensive research, the diffraction limits of QPI have not been established and examined. Hence, it remains unclear whether diffraction-affected QPI provides reliable quantification or merely visualizes phase objects, similar to phase contrast methods. Here, we develop a general diffraction phase imaging theory and show that it is intrinsically connected with Rayleigh's resolution theory. Our approach reveals the entanglement of phases under restoration, imposing diffraction bounds on spatial phase resolution and, unexpectedly, on phase accuracy. We prove that the phase accuracy depends on the size, shape, and absorption of objects forming the sample and significantly declines if the object size approaches the Rayleigh limit (a relative phase error of -16% for an Airy disk-sized object with low phase shift). We show that the phase accuracy limits can be enhanced at the cost of deteriorated phase resolution by attenuating the sample background light. The QPI diffraction limits are thoroughly examined in experiments with certified phase targets and biological cells. The study's relevance is underscored by results showing that the phase accuracy of some structures is lost (a relative phase error of -40%) even though they are spatially resolved (a phase visibility of 0.5). A reliable procedure is used to estimate phase errors in given experimental conditions, opening the way to mitigate errors' impact through data post-processing. Finally, the phase accuracy enhancement in super-resolution QPI is discovered, which has not been previously reported.
Název v anglickém jazyce
On quantitativeness of diffraction-limited quantitative phase imaging
Popis výsledku anglicky
Quantitative phase imaging (QPI) has advanced by accurately quantifying phase shifts caused by weakly absorbing biological and artificial structures. Despite extensive research, the diffraction limits of QPI have not been established and examined. Hence, it remains unclear whether diffraction-affected QPI provides reliable quantification or merely visualizes phase objects, similar to phase contrast methods. Here, we develop a general diffraction phase imaging theory and show that it is intrinsically connected with Rayleigh's resolution theory. Our approach reveals the entanglement of phases under restoration, imposing diffraction bounds on spatial phase resolution and, unexpectedly, on phase accuracy. We prove that the phase accuracy depends on the size, shape, and absorption of objects forming the sample and significantly declines if the object size approaches the Rayleigh limit (a relative phase error of -16% for an Airy disk-sized object with low phase shift). We show that the phase accuracy limits can be enhanced at the cost of deteriorated phase resolution by attenuating the sample background light. The QPI diffraction limits are thoroughly examined in experiments with certified phase targets and biological cells. The study's relevance is underscored by results showing that the phase accuracy of some structures is lost (a relative phase error of -40%) even though they are spatially resolved (a phase visibility of 0.5). A reliable procedure is used to estimate phase errors in given experimental conditions, opening the way to mitigate errors' impact through data post-processing. Finally, the phase accuracy enhancement in super-resolution QPI is discovered, which has not been previously reported.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
<a href="/cs/project/LM2023050" target="_blank" >LM2023050: Národní infrastruktura pro biologické a medicínské zobrazování</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
APL Photonics
ISSN
2378-0967
e-ISSN
—
Svazek periodika
9
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
14
Strana od-do
„126111-1“-„126111-14“
Kód UT WoS článku
001379528800001
EID výsledku v databázi Scopus
2-s2.0-85211984837