Biomechanical assessment of cannulated nails for the treatment of proximal femur fractures
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F22%3AE0109730" target="_blank" >RIV/00843989:_____/22:E0109730 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61988987:17110/22:A2302ITQ RIV/61989100:27360/22:10250246 RIV/61989100:27230/22:10250246
Výsledek na webu
<a href="https://www.mdpi.com/2076-3417/12/15/7470" target="_blank" >https://www.mdpi.com/2076-3417/12/15/7470</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/app12157470" target="_blank" >10.3390/app12157470</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Biomechanical assessment of cannulated nails for the treatment of proximal femur fractures
Popis výsledku v původním jazyce
This article focuses on a type of surgical implant used in orthopaedics and traumatology-cannulated femoral nails. Femoral nails are used in medical treatment for purposes of osteosynthesis, i.e., when treating various types of complicated fractures, in this case fractures of the femur. The article investigates cases in which a nail has been implanted in the proximal part of the femur for a short time (with the fracture still not healed), compared with cases in which the bone has already healed. According to AO classification, examined fractures are described as AO 31B3 AO 32A3. The main focus is on strength-deformation analysis using the finite element method (FEM), which makes it possible to determine the behaviour of the femur-implant system. FEM analysis was used to compare 1.4441 steel nails made by two manufacturers, Medin (Czech Republic) and Tantum (Germany). Boundary conditions including external loading, prescribed supports and elastic foundation are defined. There were solved FEM analyses for five cases of healed femur and five cases of broken femur both including implants with prescribed collo-diaphyseal angles. The results of the analysis were used to assess stress-deformation states from the perspective of appropriateness for clinical treatment, biomechanical reliability and safety. All examined femoral nails are compared, safe and suitable for patient treatment.
Název v anglickém jazyce
Biomechanical assessment of cannulated nails for the treatment of proximal femur fractures
Popis výsledku anglicky
This article focuses on a type of surgical implant used in orthopaedics and traumatology-cannulated femoral nails. Femoral nails are used in medical treatment for purposes of osteosynthesis, i.e., when treating various types of complicated fractures, in this case fractures of the femur. The article investigates cases in which a nail has been implanted in the proximal part of the femur for a short time (with the fracture still not healed), compared with cases in which the bone has already healed. According to AO classification, examined fractures are described as AO 31B3 AO 32A3. The main focus is on strength-deformation analysis using the finite element method (FEM), which makes it possible to determine the behaviour of the femur-implant system. FEM analysis was used to compare 1.4441 steel nails made by two manufacturers, Medin (Czech Republic) and Tantum (Germany). Boundary conditions including external loading, prescribed supports and elastic foundation are defined. There were solved FEM analyses for five cases of healed femur and five cases of broken femur both including implants with prescribed collo-diaphyseal angles. The results of the analysis were used to assess stress-deformation states from the perspective of appropriateness for clinical treatment, biomechanical reliability and safety. All examined femoral nails are compared, safe and suitable for patient treatment.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30211 - Orthopaedics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied sciences
ISSN
2076-3417
e-ISSN
2076-3417
Svazek periodika
12
Číslo periodika v rámci svazku
15
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
16
Strana od-do
1-16
Kód UT WoS článku
000839100500001
EID výsledku v databázi Scopus
2-s2.0-85136994938