Milk urea analytical result reliability and its methodical possibilities in the Czech Republic.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722861%3A_____%2F13%3AHA04" target="_blank" >RIV/26722861:_____/13:HA04 - isvavai.cz</a>
Výsledek na webu
<a href="http://acta.mendelu.cz/pdf/actaun201361010169.pdf" target="_blank" >http://acta.mendelu.cz/pdf/actaun201361010169.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.11118/actaun201361010169" target="_blank" >10.11118/actaun201361010169</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Milk urea analytical result reliability and its methodical possibilities in the Czech Republic.
Popis výsledku v původním jazyce
Question is milk urea concentration (MUC) result reliability improvement. MUC was investigated in 5 milk sample sets and in 7 calibration experiments. The positions of methods were changed. There were following methods for MUC (in mg.100 ml-1): ? photometric method (PH, as reference (R)); ? method Ureakvant (UK, as R) based on enzymatic change of electrical conductivity; ? method Chemspec (CH as R); ? spectroscopic method in mid IR range of spectrum (FT?MIR; indirect routine method). Between method correlation coefficients varied 0.8803 - 0.9943 (P < 0.001). The MUC R methods (UK, PH) had better values of accuracy (1.14 - 1.81) and comparable values of repeatability (0.65 - 1.83) as compared to FT?MIR.
Název v anglickém jazyce
Milk urea analytical result reliability and its methodical possibilities in the Czech Republic.
Popis výsledku anglicky
Question is milk urea concentration (MUC) result reliability improvement. MUC was investigated in 5 milk sample sets and in 7 calibration experiments. The positions of methods were changed. There were following methods for MUC (in mg.100 ml-1): ? photometric method (PH, as reference (R)); ? method Ureakvant (UK, as R) based on enzymatic change of electrical conductivity; ? method Chemspec (CH as R); ? spectroscopic method in mid IR range of spectrum (FT?MIR; indirect routine method). Between method correlation coefficients varied 0.8803 - 0.9943 (P < 0.001). The MUC R methods (UK, PH) had better values of accuracy (1.14 - 1.81) and comparable values of repeatability (0.65 - 1.83) as compared to FT?MIR.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GM - Potravinářství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/QJ1210301" target="_blank" >QJ1210301: Výzkum, nové produkty a služby pro vytvoření centra prevence, detekce a podpory léčby mastitid.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Universitatis Agriculturae et Silviculturae Mendelianae Brunensis
ISSN
1211-8516
e-ISSN
—
Svazek periodika
LXI
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
18
Strana od-do
169-186
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—