Experimental Validation of the Biomechanical Response of an Anthropomorphic Testing Device (Dummy) at Low Impact Velocities
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F44555601%3A13420%2F23%3A43898196" target="_blank" >RIV/44555601:13420/23:43898196 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21220/23:00371931 RIV/00216208:11510/23:10469582
Výsledek na webu
<a href="https://journalmt.com/artkey/mft-202304-0002_experimental-validation-of-the-biomechanical-response-of-an-anthropo-morphic-testing-device-dummy-at-low-impa.php" target="_blank" >https://journalmt.com/artkey/mft-202304-0002_experimental-validation-of-the-biomechanical-response-of-an-anthropo-morphic-testing-device-dummy-at-low-impa.php</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.21062/mft.2023.047" target="_blank" >10.21062/mft.2023.047</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experimental Validation of the Biomechanical Response of an Anthropomorphic Testing Device (Dummy) at Low Impact Velocities
Popis výsledku v původním jazyce
The paper describes the experimental validation of the biomechanical response of the Hybrid III 50th Percentile Male Pedestrian Dummy (JASTI, Tokyo, Japan) at low impact velocity (up to 2.2 m/s) in comparison with that of human probands. The paper is based on previous research that was focused on the tram-pedestrian crash tests using the same dummy. The biofidelity of dummy was analysed in two collision scenarios: the anteroposterior impact (chest impact) and lateral impact (shoulder impact) using a unique pendulum impact testing machine of own design and construction. The primary outcome variable was the peak resultant acceleration of the head and chest during the impact. Based on the lab-based measurements, the unique impact testing machine was found adequate and precise for the purposes of future crash-test analyses in the area of automotive industry. The proposed methodology and measurement protocol were shown proper to compare the data between the dummy and human participants. Following the pilot experiments, the kinematic and dynamic data between the dummy and human participants were analysed to assess the biofidelity of dummy for the frontal and side impact during tram-pedestrian collisions at low impact velocities.
Název v anglickém jazyce
Experimental Validation of the Biomechanical Response of an Anthropomorphic Testing Device (Dummy) at Low Impact Velocities
Popis výsledku anglicky
The paper describes the experimental validation of the biomechanical response of the Hybrid III 50th Percentile Male Pedestrian Dummy (JASTI, Tokyo, Japan) at low impact velocity (up to 2.2 m/s) in comparison with that of human probands. The paper is based on previous research that was focused on the tram-pedestrian crash tests using the same dummy. The biofidelity of dummy was analysed in two collision scenarios: the anteroposterior impact (chest impact) and lateral impact (shoulder impact) using a unique pendulum impact testing machine of own design and construction. The primary outcome variable was the peak resultant acceleration of the head and chest during the impact. Based on the lab-based measurements, the unique impact testing machine was found adequate and precise for the purposes of future crash-test analyses in the area of automotive industry. The proposed methodology and measurement protocol were shown proper to compare the data between the dummy and human participants. Following the pilot experiments, the kinematic and dynamic data between the dummy and human participants were analysed to assess the biofidelity of dummy for the frontal and side impact during tram-pedestrian collisions at low impact velocities.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20302 - Applied mechanics
Návaznosti výsledku
Projekt
—
Návaznosti
O - Projekt operacniho programu
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Manufacturing Technology
ISSN
1213-2489
e-ISSN
2787-9402
Svazek periodika
23
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
418-425
Kód UT WoS článku
001062143100003
EID výsledku v databázi Scopus
2-s2.0-85172292179