Composite fibrous glaucoma drainage implant
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24210%2F17%3A00004806" target="_blank" >RIV/46747885:24210/17:00004806 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/46747885:24410/17:00004806
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1757-899X/254/6/062006" target="_blank" >http://dx.doi.org/10.1088/1757-899X/254/6/062006</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/254/6/062006" target="_blank" >10.1088/1757-899X/254/6/062006</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Composite fibrous glaucoma drainage implant
Popis výsledku v původním jazyce
Glaucoma is a frequent reason of loss vision. It is usually caused by increased intraocular pressure leading to damage of optic nerve head. This work deals with the development of fibrous structure suitable for glaucoma drainage implants (GDI). Commercially produced metallic glaucoma implants are very effective in lowering intraocular pressure. However, these implants may cause adverse events such as damage to adjacent tissue, fibrosis, hypotony or many others [1]. The aim of this study is to reduce undesirable properties of currently produced drains and improve their properties by creating of the composite fibrous drain for achieve a normal intraocular pressure. Two types of electrospinning technologies were used for the production of very small tubular implants. First type was focused for production of outer part of tubular drain and the second type of electrospinning method made the inner part of shape follows the connections of both parts. Complete implant had a special properties suitable for drainage of fluid. Morphological parameters, liquid transport tests and in-vitro cell adhesion tests were detected.
Název v anglickém jazyce
Composite fibrous glaucoma drainage implant
Popis výsledku anglicky
Glaucoma is a frequent reason of loss vision. It is usually caused by increased intraocular pressure leading to damage of optic nerve head. This work deals with the development of fibrous structure suitable for glaucoma drainage implants (GDI). Commercially produced metallic glaucoma implants are very effective in lowering intraocular pressure. However, these implants may cause adverse events such as damage to adjacent tissue, fibrosis, hypotony or many others [1]. The aim of this study is to reduce undesirable properties of currently produced drains and improve their properties by creating of the composite fibrous drain for achieve a normal intraocular pressure. Two types of electrospinning technologies were used for the production of very small tubular implants. First type was focused for production of outer part of tubular drain and the second type of electrospinning method made the inner part of shape follows the connections of both parts. Complete implant had a special properties suitable for drainage of fluid. Morphological parameters, liquid transport tests and in-vitro cell adhesion tests were detected.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
21001 - Nano-materials (production and properties)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IOP Conference Series: Materials Science and Engineering
ISBN
—
ISSN
1757-8981
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
Institute of Physics Publishing (IOP Science)
Místo vydání
—
Místo konání akce
Corfu, Greece
Datum konání akce
1. 1. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000417214900055