Influence assesment of autotransformer remanent flux on resonance overvoltage
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F20%3A43959152" target="_blank" >RIV/49777513:23220/20:43959152 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.scientificbulletin.upb.ro/rev_docs_arhiva/rez5fb_214990.pdf" target="_blank" >https://www.scientificbulletin.upb.ro/rev_docs_arhiva/rez5fb_214990.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence assesment of autotransformer remanent flux on resonance overvoltage
Popis výsledku v původním jazyce
Abnormal resonance overvoltagesoccur due to the emergence of non-sinusoidal modes of bulk electrical networks. The considered type of overvoltage refers to durable internal overvoltages, which have characteristics that can exceed the maximum permissible magnitude with a certain correlation of the values of the parameters of the extra high voltage power transmission line 750 kV. A typical example of a non-sinusoidal mode of operation of an extra high voltage line is the mode of switching on the line to an unloaded autotransformer. The paper analyzes the effect of remanent magnetization of an unloaded autotransformer on resonance overvoltages. To remove the remanent magnetization of the autotransformer, a set of effective measures for suppressing resonance overvoltages has been proposed.
Název v anglickém jazyce
Influence assesment of autotransformer remanent flux on resonance overvoltage
Popis výsledku anglicky
Abnormal resonance overvoltagesoccur due to the emergence of non-sinusoidal modes of bulk electrical networks. The considered type of overvoltage refers to durable internal overvoltages, which have characteristics that can exceed the maximum permissible magnitude with a certain correlation of the values of the parameters of the extra high voltage power transmission line 750 kV. A typical example of a non-sinusoidal mode of operation of an extra high voltage line is the mode of switching on the line to an unloaded autotransformer. The paper analyzes the effect of remanent magnetization of an unloaded autotransformer on resonance overvoltages. To remove the remanent magnetization of the autotransformer, a set of effective measures for suppressing resonance overvoltages has been proposed.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
UPB Scientific Bulletin, Series C: Electrical Engineering and Computer Science
ISSN
2286-3540
e-ISSN
—
Svazek periodika
82
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
RO - Rumunsko
Počet stran výsledku
18
Strana od-do
233-250
Kód UT WoS článku
000557847800018
EID výsledku v databázi Scopus
2-s2.0-85089164706