Numerical analysis of non-Newtonian blood flow and wall shear stress in realistic single, double and triple aorto-coronary bypasses
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23520%2F13%3A43919259" target="_blank" >RIV/49777513:23520/13:43919259 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/cnm.2560" target="_blank" >http://dx.doi.org/10.1002/cnm.2560</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/cnm.2560" target="_blank" >10.1002/cnm.2560</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Numerical analysis of non-Newtonian blood flow and wall shear stress in realistic single, double and triple aorto-coronary bypasses
Popis výsledku v původním jazyce
Considering the fact that hemodynamics plays an important role in the patency and overall performance of implanted bypass grafts, this work presents a numerical investigation of pulsatile non-Newtonian blood flow in three different patient-specific aorto-coronary bypasses. The three bypass models are distinguished from each other by the number of distal side-to-side and end-to-side anastomoses and denoted as single, double and triple bypasses. The mathematical model in the form of time-dependent nonlinear system of incompressible Navier?Stokes equations is coupled with the Carreau?Yasuda model describing the shear-thinning property of human blood and numerically solved using the principle of the SIMPLE algorithm and cell-centred finite volume method formulated for hybrid unstructured tetrahedral grids. The numerical results computed for non-Newtonian and Newtonian blood flow in the three aorto-coronary bypasses are compared and analysed with emphasis placed on the distribution of cycle
Název v anglickém jazyce
Numerical analysis of non-Newtonian blood flow and wall shear stress in realistic single, double and triple aorto-coronary bypasses
Popis výsledku anglicky
Considering the fact that hemodynamics plays an important role in the patency and overall performance of implanted bypass grafts, this work presents a numerical investigation of pulsatile non-Newtonian blood flow in three different patient-specific aorto-coronary bypasses. The three bypass models are distinguished from each other by the number of distal side-to-side and end-to-side anastomoses and denoted as single, double and triple bypasses. The mathematical model in the form of time-dependent nonlinear system of incompressible Navier?Stokes equations is coupled with the Carreau?Yasuda model describing the shear-thinning property of human blood and numerically solved using the principle of the SIMPLE algorithm and cell-centred finite volume method formulated for hybrid unstructured tetrahedral grids. The numerical results computed for non-Newtonian and Newtonian blood flow in the three aorto-coronary bypasses are compared and analysed with emphasis placed on the distribution of cycle
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.1.00%2F02.0090" target="_blank" >ED1.1.00/02.0090: NTIS - Nové technologie pro informační společnost</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal for Numerical Methods in Biomedical Engineering
ISSN
2040-7939
e-ISSN
—
Svazek periodika
29
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
25
Strana od-do
1057-1081
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—