Optimal sensor distribution for impact loading identification
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23520%2F14%3A43923049" target="_blank" >RIV/49777513:23520/14:43923049 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optimal sensor distribution for impact loading identification
Popis výsledku v původním jazyce
Problem of optimal sensor distribution for impact loading identification was studied on the composite airfoil segment. The segment is made of glass-epoxy composite with piezoelectric transducers glued on its surface. Numerical model of segment was assembled in finite element software Abaqus. The experimental modal analysis was performed and its results were compared to the results obtained from numerical model. Material parameters were adjusted using optimization where the difference between numerical and experimental results mentioned above was minimized. Furthermore, the segment was loaded by impactor and response was measured by piezoelectric transducer in selected location. The response was compared to one obtained numerically. Adjusted model was used for determination of optimal sensor distribution.
Název v anglickém jazyce
Optimal sensor distribution for impact loading identification
Popis výsledku anglicky
Problem of optimal sensor distribution for impact loading identification was studied on the composite airfoil segment. The segment is made of glass-epoxy composite with piezoelectric transducers glued on its surface. Numerical model of segment was assembled in finite element software Abaqus. The experimental modal analysis was performed and its results were compared to the results obtained from numerical model. Material parameters were adjusted using optimization where the difference between numerical and experimental results mentioned above was minimized. Furthermore, the segment was loaded by impactor and response was measured by piezoelectric transducer in selected location. The response was compared to one obtained numerically. Adjusted model was used for determination of optimal sensor distribution.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
JI - Kompositní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů