Inconsistency between Human Observation and Deep Learning Models: Assessing Validity of Postmortem Computed Tomography Diagnosis of Drowning
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60076658%3A12310%2F24%3A43908843" target="_blank" >RIV/60076658:12310/24:43908843 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21220/24:00378865
Výsledek na webu
<a href="https://link.springer.com/article/10.1007/s10278-024-00974-6" target="_blank" >https://link.springer.com/article/10.1007/s10278-024-00974-6</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10278-024-00974-6" target="_blank" >10.1007/s10278-024-00974-6</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Inconsistency between Human Observation and Deep Learning Models: Assessing Validity of Postmortem Computed Tomography Diagnosis of Drowning
Popis výsledku v původním jazyce
Drowning diagnosis is a complicated process in the autopsy, even with the assistance of autopsy imaging and the on-site information from where the body was found. Previous studies have developed well-performed deep learning (DL) models for drowning diagnosis. However, the validity of the DL models was not assessed, raising doubts about whether the learned features accurately represented the medical findings observed by human experts. In this paper, we assessed the medical validity of DL models that had achieved high classification performance for drowning diagnosis. This retrospective study included autopsy cases aged 8-91 years who underwent postmortem computed tomography between 2012 and 2021 (153 drowning and 160 non-drowning cases). We first trained three deep learning models from a previous work and generated saliency maps that highlight important features in the input. To assess the validity of models, pixel-level annotations were created by four radiological technologists and further quantitatively compared with the saliency maps. All the three models demonstrated high classification performance with areas under the receiver operating characteristic curves of 0.94, 0.97, and 0.98, respectively. On the other hand, the assessment results revealed unexpected inconsistency between annotations and models' saliency maps. In fact, each model had, respectively, around 30%, 40%, and 80% of irrelevant areas in the saliency maps, suggesting the predictions of the DL models might be unreliable. The result alerts us in the careful assessment of DL tools, even those with high classification performance.
Název v anglickém jazyce
Inconsistency between Human Observation and Deep Learning Models: Assessing Validity of Postmortem Computed Tomography Diagnosis of Drowning
Popis výsledku anglicky
Drowning diagnosis is a complicated process in the autopsy, even with the assistance of autopsy imaging and the on-site information from where the body was found. Previous studies have developed well-performed deep learning (DL) models for drowning diagnosis. However, the validity of the DL models was not assessed, raising doubts about whether the learned features accurately represented the medical findings observed by human experts. In this paper, we assessed the medical validity of DL models that had achieved high classification performance for drowning diagnosis. This retrospective study included autopsy cases aged 8-91 years who underwent postmortem computed tomography between 2012 and 2021 (153 drowning and 160 non-drowning cases). We first trained three deep learning models from a previous work and generated saliency maps that highlight important features in the input. To assess the validity of models, pixel-level annotations were created by four radiological technologists and further quantitatively compared with the saliency maps. All the three models demonstrated high classification performance with areas under the receiver operating characteristic curves of 0.94, 0.97, and 0.98, respectively. On the other hand, the assessment results revealed unexpected inconsistency between annotations and models' saliency maps. In fact, each model had, respectively, around 30%, 40%, and 80% of irrelevant areas in the saliency maps, suggesting the predictions of the DL models might be unreliable. The result alerts us in the careful assessment of DL tools, even those with high classification performance.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Imaging Informatics in Medicine
ISSN
2948-2925
e-ISSN
2948-2933
Svazek periodika
37
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
935-944
Kód UT WoS článku
001248218600025