Screening of blood-brain barrier penetration using the immobilized artificial membrane phosphatidylcholine column chromatography at the physiological pH
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG44__%2F13%3A43874974" target="_blank" >RIV/60162694:G44__/13:43874974 - isvavai.cz</a>
Výsledek na webu
<a href="http://mmsl.cz/viCMS/soubory/pdf/MMSL_2013_2_2_WWW.pdf" target="_blank" >http://mmsl.cz/viCMS/soubory/pdf/MMSL_2013_2_2_WWW.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Screening of blood-brain barrier penetration using the immobilized artificial membrane phosphatidylcholine column chromatography at the physiological pH
Popis výsledku v původním jazyce
In this study, 21 structurally diverse drugs with examined central nervous system penetration were used for prediction of blood-brain barrier penetration using HPLC-UV instrument. Drugs' chromatographic capacity factors were measured by the immobilized artificial membrane presented by phosphatidylcholine column. The correlation between chromatographic capacity factor, octanol-water partition coefficient (log P) and molecular polar surface area (PSA) were determined at the physiological pH. The correlation factor 0.6677 with respect to log P and 0.7199 in reference to PSA was assigned. The developed in vitro prediction method may be used as a screening tool for blood-brain barrier penetration of drugs with passive transport mechanism.
Název v anglickém jazyce
Screening of blood-brain barrier penetration using the immobilized artificial membrane phosphatidylcholine column chromatography at the physiological pH
Popis výsledku anglicky
In this study, 21 structurally diverse drugs with examined central nervous system penetration were used for prediction of blood-brain barrier penetration using HPLC-UV instrument. Drugs' chromatographic capacity factors were measured by the immobilized artificial membrane presented by phosphatidylcholine column. The correlation between chromatographic capacity factor, octanol-water partition coefficient (log P) and molecular polar surface area (PSA) were determined at the physiological pH. The correlation factor 0.6677 with respect to log P and 0.7199 in reference to PSA was assigned. The developed in vitro prediction method may be used as a screening tool for blood-brain barrier penetration of drugs with passive transport mechanism.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
KA - Vojenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP303%2F11%2F1907" target="_blank" >GAP303/11/1907: Nové inhibitory acetylcholinesterasy odvozené od látky 7-MEOTA - potenciální léčiva pro Alzheimerovu nemoc</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Military Medical Science Letters
ISSN
0372-7025
e-ISSN
—
Svazek periodika
82
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
55-62
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—