QCM immunosensor for the determination of Staphylococcus aureus antigen
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG44__%2F20%3A00555659" target="_blank" >RIV/60162694:G44__/20:00555659 - isvavai.cz</a>
Výsledek na webu
<a href="https://link.springer.com/article/10.1007%2Fs11696-019-00889-5" target="_blank" >https://link.springer.com/article/10.1007%2Fs11696-019-00889-5</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s11696-019-00889-5" target="_blank" >10.1007/s11696-019-00889-5</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
QCM immunosensor for the determination of Staphylococcus aureus antigen
Popis výsledku v původním jazyce
Staphylococcus aureus is a causative agent of infectious diseases and a producer of a group of highly toxic proteins called Staphylococcal enterotoxins. Currently, the presence of S. aureus in a sample can be determined by a wide spectrum of genetic, immunochemical and microbiological techniques. Despite availability of standard methods and devices, they are not fully suitable for a simple, label-free mode of use by an unskilled worker. In this paper, a biosensor based on quartz crystal microbalance (QCM) sensor is performed as a tool for a simple and reliable determination of S. aureus. The biosensor contained an antibody specific to S. aureus immobilized through protein A on 10 MHz QCM sensors and the interdigitated layer was stabilized by iron nanoparticles. The assay was performed as label free and sample was applied without any pretreatment. Limit of detection 145 mu g/ml (5.18 x 10(8) CFU/ml) was achieved. When considered standard size of a sample 50 mu l, the limit of detection was equal to 7.25 mu g (2.59 x -10(7) CFU). The biosensors kept more than 90% sensitivity to the analyte after storage in laboratory conditions for 90 days. Good correlation to standard enzyme-linked immunosorbent assay was also proved. The biosensor appears as a simple but reliable tool for S. aureus assay and the QCM platform would provide further applications in microbial analyses.
Název v anglickém jazyce
QCM immunosensor for the determination of Staphylococcus aureus antigen
Popis výsledku anglicky
Staphylococcus aureus is a causative agent of infectious diseases and a producer of a group of highly toxic proteins called Staphylococcal enterotoxins. Currently, the presence of S. aureus in a sample can be determined by a wide spectrum of genetic, immunochemical and microbiological techniques. Despite availability of standard methods and devices, they are not fully suitable for a simple, label-free mode of use by an unskilled worker. In this paper, a biosensor based on quartz crystal microbalance (QCM) sensor is performed as a tool for a simple and reliable determination of S. aureus. The biosensor contained an antibody specific to S. aureus immobilized through protein A on 10 MHz QCM sensors and the interdigitated layer was stabilized by iron nanoparticles. The assay was performed as label free and sample was applied without any pretreatment. Limit of detection 145 mu g/ml (5.18 x 10(8) CFU/ml) was achieved. When considered standard size of a sample 50 mu l, the limit of detection was equal to 7.25 mu g (2.59 x -10(7) CFU). The biosensors kept more than 90% sensitivity to the analyte after storage in laboratory conditions for 90 days. Good correlation to standard enzyme-linked immunosorbent assay was also proved. The biosensor appears as a simple but reliable tool for S. aureus assay and the QCM platform would provide further applications in microbial analyses.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10400 - Chemical sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemical Papers
ISSN
2585-7290
e-ISSN
1336-9075
Svazek periodika
74
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
8
Strana od-do
451-458
Kód UT WoS článku
000514312600007
EID výsledku v databázi Scopus
2-s2.0-85069875607