Evaluation of a carrier control valve for a direct nozzle injection system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41310%2F09%3A27918" target="_blank" >RIV/60460709:41310/09:27918 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of a carrier control valve for a direct nozzle injection system
Popis výsledku v původním jazyce
Environmental friendly pesticide application technologies, utilising direct injection systems and simple patch spraying, have become more important in recent years. During site-specific application, sprays are turned off over areas to be excluded and onover areas to be treated. Thus, to obtain spatially accurate applications, the spray patterns from nozzles have to be rapidly established. An electro-pneumatic carrier valve, in combination with a direct nozzle injection system, has been tested to determine its suitability for sitespecific application. Also, the effect of interrupting the flow of carrier fluid on the injection process has been assessed. A high-speed camera was used to study the valve response time and the development of the spray pattern. The increase in concentration of pesticide in the direct nozzle injection system was simulated by a NaCl solution, which was measured using a conductivity sensor. The reaction time of the electro-pneumatic valve was less than 32 ms ope
Název v anglickém jazyce
Evaluation of a carrier control valve for a direct nozzle injection system
Popis výsledku anglicky
Environmental friendly pesticide application technologies, utilising direct injection systems and simple patch spraying, have become more important in recent years. During site-specific application, sprays are turned off over areas to be excluded and onover areas to be treated. Thus, to obtain spatially accurate applications, the spray patterns from nozzles have to be rapidly established. An electro-pneumatic carrier valve, in combination with a direct nozzle injection system, has been tested to determine its suitability for sitespecific application. Also, the effect of interrupting the flow of carrier fluid on the injection process has been assessed. A high-speed camera was used to study the valve response time and the development of the spray pattern. The increase in concentration of pesticide in the direct nozzle injection system was simulated by a NaCl solution, which was measured using a conductivity sensor. The reaction time of the electro-pneumatic valve was less than 32 ms ope
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GA - Zemědělská ekonomie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biosystems Engineering
ISSN
1537-5110
e-ISSN
—
Svazek periodika
103
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—