Biochemical Detection of Cholinesterase Inhibitors in Water with a New Two-Component Chromogenic Reagent
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22320%2F18%3A43915528" target="_blank" >RIV/60461373:22320/18:43915528 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62157124:16370/18:43876651
Výsledek na webu
<a href="https://link.springer.com/article/10.1134/S1061934818090101" target="_blank" >https://link.springer.com/article/10.1134/S1061934818090101</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1134/S1061934818090101" target="_blank" >10.1134/S1061934818090101</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Biochemical Detection of Cholinesterase Inhibitors in Water with a New Two-Component Chromogenic Reagent
Popis výsledku v původním jazyce
We propose a simple biochemical detector of cholinesterase inhibitors in water that is based on an enzymatic reaction. The detector was designed as a detection tube containing (i) an indication layer with an immobilized butyrylcholinesterase, (ii) a layer with substrate and chromogenic reagent and (iii) an ampoule with buffer. The chromogenic reagent contained a mixture of two triphenylmethane dyes: Guinea Green B and Fuschsin Basic. The absence of inhibitors was indicated by changing the blue color of the indication layer to violet-red. In the presence of inhibitors, the indication layer remained blue-colored. Color change was evaluated visually (by naked eye). The functionality of the detector was verified on aqueous solutions of alkaloid physostigmine and two chemical warfare agents: sarin and VX. The achieved detection limits were 0.01 μg/mL for physostigmine and sarin and 0.005 μg/mL for VX.
Název v anglickém jazyce
Biochemical Detection of Cholinesterase Inhibitors in Water with a New Two-Component Chromogenic Reagent
Popis výsledku anglicky
We propose a simple biochemical detector of cholinesterase inhibitors in water that is based on an enzymatic reaction. The detector was designed as a detection tube containing (i) an indication layer with an immobilized butyrylcholinesterase, (ii) a layer with substrate and chromogenic reagent and (iii) an ampoule with buffer. The chromogenic reagent contained a mixture of two triphenylmethane dyes: Guinea Green B and Fuschsin Basic. The absence of inhibitors was indicated by changing the blue color of the indication layer to violet-red. In the presence of inhibitors, the indication layer remained blue-colored. Color change was evaluated visually (by naked eye). The functionality of the detector was verified on aqueous solutions of alkaloid physostigmine and two chemical warfare agents: sarin and VX. The achieved detection limits were 0.01 μg/mL for physostigmine and sarin and 0.005 μg/mL for VX.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/TA04011060" target="_blank" >TA04011060: Technologie pro nový kolorimetrický trubičkový biosenzor inhibitorů cholinesteráz v ovzduší i v kapalných vzorcích</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF ANALYTICAL CHEMISTRY
ISSN
1061-9348
e-ISSN
—
Svazek periodika
73
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
RU - Ruská federace
Počet stran výsledku
6
Strana od-do
900-905
Kód UT WoS článku
000443826400009
EID výsledku v databázi Scopus
2-s2.0-85052890296