Solid phase microextraction-comprehensive two-dimensional gas chromatography?time-of-flight mass spectrometry for the analysis of honey volatiles
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F07%3A00022454" target="_blank" >RIV/60461373:22330/07:00022454 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Solid phase microextraction-comprehensive two-dimensional gas chromatography?time-of-flight mass spectrometry for the analysis of honey volatiles
Popis výsledku v původním jazyce
Head-space solid phase microextration (SPME), followed by comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GC x GC-TOFMS), has been implemented for the analysis of honey volatiles, with emphasis on the optimal selectionof SPME fibre and the first- and second-dimension GC capillaries. From seven SPME fibres investigated, a divinylbenzene/Carboxen/polydimethylsiloxane (DVB/CAR/PDMS) 50/30 mu m fibre provided the best sorption capacity and the broadest range of volatilesextracted from the headspace of a mixed honey sample. A combination of DB-5ms x SUPELCOWAX 10 columns enabled the best resolution of sample components compared to the other two tested column configurations. Employing this powerful analytical strategy ledto the identification of 164 volatile compounds present in a honey mixture during a 19-min GC run. Combination of this simple and inexpensive SPME-based sampling/concentration technique with the advanced separation/identification approac
Název v anglickém jazyce
Solid phase microextraction-comprehensive two-dimensional gas chromatography?time-of-flight mass spectrometry for the analysis of honey volatiles
Popis výsledku anglicky
Head-space solid phase microextration (SPME), followed by comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GC x GC-TOFMS), has been implemented for the analysis of honey volatiles, with emphasis on the optimal selectionof SPME fibre and the first- and second-dimension GC capillaries. From seven SPME fibres investigated, a divinylbenzene/Carboxen/polydimethylsiloxane (DVB/CAR/PDMS) 50/30 mu m fibre provided the best sorption capacity and the broadest range of volatilesextracted from the headspace of a mixed honey sample. A combination of DB-5ms x SUPELCOWAX 10 columns enabled the best resolution of sample components compared to the other two tested column configurations. Employing this powerful analytical strategy ledto the identification of 164 volatile compounds present in a honey mixture during a 19-min GC run. Combination of this simple and inexpensive SPME-based sampling/concentration technique with the advanced separation/identification approac
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GM - Potravinářství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Separation Sciences
ISSN
1615-9306
e-ISSN
—
Svazek periodika
—
Číslo periodika v rámci svazku
30
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
13
Strana od-do
—
Kód UT WoS článku
000245143700011
EID výsledku v databázi Scopus
—