Implemetation of GCxGC-TOF MS for the Simultaneous Determination of PCBs, PBDEs and PAHs in Environmental Samples.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F10%3A00024384" target="_blank" >RIV/60461373:22330/10:00024384 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Implemetation of GCxGC-TOF MS for the Simultaneous Determination of PCBs, PBDEs and PAHs in Environmental Samples.
Popis výsledku v původním jazyce
In this study, comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GCxGC-TOFMS) for the simultaneous determination of 18 polychlorinated biphenyls (PCBs), 7 polybrominated diphenyl ethers (PBDEs) and 16 polycyclic aromatic hydrocarbons (PAHs) was optimized to obtain the best chromatographic resolution and quantification limits (LOQs) of target analytes. Two injection techniques, pulsed splitless and large volume programmable temperature vaporization (LV-PTV), and several capillary column systems were tested within the experiments (BPX-5 and BPX-50 in the 1st dimension and BPX-50, Rt-LC35 and HT-8 in 2nd dimension). All tested combinations of columns were able to separate all target PCBs and PBDEs. Selection ofthe column system was therefore mainly influenced by its ability to separate the critical groups of PAHs (1st group: B[a]A, CP[cd]P and Chr, 2nd group B[f]F, B[k]F and B[b]F, 3rd group DB[ah]A, I[1,2,3-cd]P and B[ghi]P). Although none of
Název v anglickém jazyce
Implemetation of GCxGC-TOF MS for the Simultaneous Determination of PCBs, PBDEs and PAHs in Environmental Samples.
Popis výsledku anglicky
In this study, comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GCxGC-TOFMS) for the simultaneous determination of 18 polychlorinated biphenyls (PCBs), 7 polybrominated diphenyl ethers (PBDEs) and 16 polycyclic aromatic hydrocarbons (PAHs) was optimized to obtain the best chromatographic resolution and quantification limits (LOQs) of target analytes. Two injection techniques, pulsed splitless and large volume programmable temperature vaporization (LV-PTV), and several capillary column systems were tested within the experiments (BPX-5 and BPX-50 in the 1st dimension and BPX-50, Rt-LC35 and HT-8 in 2nd dimension). All tested combinations of columns were able to separate all target PCBs and PBDEs. Selection ofthe column system was therefore mainly influenced by its ability to separate the critical groups of PAHs (1st group: B[a]A, CP[cd]P and Chr, 2nd group B[f]F, B[k]F and B[b]F, 3rd group DB[ah]A, I[1,2,3-cd]P and B[ghi]P). Although none of
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
GM - Potravinářství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/7E08068" target="_blank" >7E08068: CONtaminants in Food and Feed: Inexpensive DEtectioN for Control of Exposure</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
6th International Student Conference;Modern Analytical chemistry
ISBN
978-80-7444-005-2
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
Univerzita Karlova v Praze
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
1. 1. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—