Analysis of multiple mycotoxins under ambient conditions using direct analysis in real time (DART) ionization coupled to high resolution mass spectrometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F10%3A00024401" target="_blank" >RIV/60461373:22330/10:00024401 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of multiple mycotoxins under ambient conditions using direct analysis in real time (DART) ionization coupled to high resolution mass spectrometry
Popis výsledku v původním jazyce
Direct analysis in real time (DART) ionization coupled to an (ultra)high resolution mass spectrometer based on orbitrap technology (orbitrapMS) was used for rapid quantitative analysis of multiple mycotoxins isolated from wheat and maize by modified QuEChERS procedure. After initial evaluation of ionization efficiencies for major groups of mycotoxins achievable with DART technology, sample preparation procedure and instrument parameter settings were optimized to obtain sensitive and accurate determination of most intensively ionizing toxins (deoxynivalenol, nivalenol, zearalenon, actyldeoxynivalenol, deepoxy-deoxynivalenol, fusarenon-X, altenuene, alternariol, alternariolmethylether, diacetoxyscirpenol, sterigmatocystin). The lowest calibration levels(LCLs) estimated for the respective analytes ranged from 50 to 150?gkg-1. Quantitative analysis was performed either with the use of matrix-matched standards or by employing commercially available 13C-labeled internal standards (available
Název v anglickém jazyce
Analysis of multiple mycotoxins under ambient conditions using direct analysis in real time (DART) ionization coupled to high resolution mass spectrometry
Popis výsledku anglicky
Direct analysis in real time (DART) ionization coupled to an (ultra)high resolution mass spectrometer based on orbitrap technology (orbitrapMS) was used for rapid quantitative analysis of multiple mycotoxins isolated from wheat and maize by modified QuEChERS procedure. After initial evaluation of ionization efficiencies for major groups of mycotoxins achievable with DART technology, sample preparation procedure and instrument parameter settings were optimized to obtain sensitive and accurate determination of most intensively ionizing toxins (deoxynivalenol, nivalenol, zearalenon, actyldeoxynivalenol, deepoxy-deoxynivalenol, fusarenon-X, altenuene, alternariol, alternariolmethylether, diacetoxyscirpenol, sterigmatocystin). The lowest calibration levels(LCLs) estimated for the respective analytes ranged from 50 to 150?gkg-1. Quantitative analysis was performed either with the use of matrix-matched standards or by employing commercially available 13C-labeled internal standards (available
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GM - Potravinářství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/2B08049" target="_blank" >2B08049: Volné a vázané formy fusariových mykotoxinů v cereáliích a produktech zpracovatelských technologií, strategie kontroly a možnosti minimalizace.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Talanta
ISSN
0039-9140
e-ISSN
—
Svazek periodika
82
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
000283903300047
EID výsledku v databázi Scopus
—