Direct analysis in real time high-resolution mass spectrometry for high-throughput analysis of antiparasitic veterinary drugs in feed and food
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F12%3A43894800" target="_blank" >RIV/60461373:22330/12:43894800 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/rcm.6466" target="_blank" >http://dx.doi.org/10.1002/rcm.6466</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/rcm.6466" target="_blank" >10.1002/rcm.6466</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Direct analysis in real time high-resolution mass spectrometry for high-throughput analysis of antiparasitic veterinary drugs in feed and food
Popis výsledku v původním jazyce
RATIONALE: Direct analysis in real time (DART) is a novel ionization technique that has been demonstrated in numerous applications as a useful tool for fast and convenient mass spectrometry (MS)-based analysis of complex samples. In this study, the feasibility of DART ionization coupled to a high-resolution mass spectrometer utilizing an orbitrap mass analyzer (orbitrap MS) for high-throughput analysis of antiparasitic veterinary drugs was explored. METHODS: To obtain the best DART-orbitrap MS performance, stepwise optimization of instrumental parameter settings, such as ionization gas temperature and mass resolving power, was performed. The optimized method was applied to feed and bovine milk samples previously extracted following a QuEChERS-like strategy. RESULTS: Most antiparasitic drugs could be analyzed following the described method. Positive DART ionization provided the protonated molecules [M+H](+) ; in negative DART ion mode, deprotonated molecules [M-H](-) were observed. As a
Název v anglickém jazyce
Direct analysis in real time high-resolution mass spectrometry for high-throughput analysis of antiparasitic veterinary drugs in feed and food
Popis výsledku anglicky
RATIONALE: Direct analysis in real time (DART) is a novel ionization technique that has been demonstrated in numerous applications as a useful tool for fast and convenient mass spectrometry (MS)-based analysis of complex samples. In this study, the feasibility of DART ionization coupled to a high-resolution mass spectrometer utilizing an orbitrap mass analyzer (orbitrap MS) for high-throughput analysis of antiparasitic veterinary drugs was explored. METHODS: To obtain the best DART-orbitrap MS performance, stepwise optimization of instrumental parameter settings, such as ionization gas temperature and mass resolving power, was performed. The optimized method was applied to feed and bovine milk samples previously extracted following a QuEChERS-like strategy. RESULTS: Most antiparasitic drugs could be analyzed following the described method. Positive DART ionization provided the protonated molecules [M+H](+) ; in negative DART ion mode, deprotonated molecules [M-H](-) were observed. As a
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GM - Potravinářství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Rapid Communications in Mass Spectrometry
ISSN
0951-4198
e-ISSN
—
Svazek periodika
27
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
467-475
Kód UT WoS článku
000312888100011
EID výsledku v databázi Scopus
—