Supercritical fluid chromatography coupled to high-resolution tandem mass spectrometry: an innovative one-run method for the comprehensive assessment of chocolate quality and authenticity
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F22%3A43925068" target="_blank" >RIV/60461373:22330/22:43925068 - isvavai.cz</a>
Výsledek na webu
<a href="https://link.springer.com/article/10.1007/s00216-022-04246-6" target="_blank" >https://link.springer.com/article/10.1007/s00216-022-04246-6</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00216-022-04246-6" target="_blank" >10.1007/s00216-022-04246-6</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Supercritical fluid chromatography coupled to high-resolution tandem mass spectrometry: an innovative one-run method for the comprehensive assessment of chocolate quality and authenticity
Popis výsledku v původním jazyce
To assess chocolate quality and authenticity comprehensively, a combination of various analytical procedures is involved, thereby making the process time-consuming and costly. Thus, we investigated the potential of ultra-high performance supercritical fluid chromatography coupled to quadrupole-time of flight mass spectrometry (UHPSFC-QTOF-MS) as an alternative to “classic” methods. By combining hexane and aqueous extracts from sequential extraction, a single 8-min analytical run enabled us (i) to determine cocoa butter equivalents (CBEs) and milk fat content based on the detection of selected triacylglycerols, (ii) to calculate dry non-fat cocoa solids based on determined theobromine and caffeine content, and (iii) to profile contained sugars. To obtain the most comprehensive information about sample composition, the MS method comprised a full MS scan for non-target screening and several time-scheduled targeted MS/MS functions (“parallel reaction monitoring”) optimized according to the possible concentration ranges of the analytes. For 40 different chocolate samples, our results and those obtained by using standard methods (LC-UV for non-fat cocoa solids, and GC-FID for CBEs) were in good agreement. Compared to the conventional approach for chocolate quality and authenticity control, the presented SFC-MS method is a fast, cost-effective, and efficient alternative, and only samples suspicious for the presence of CBE should be referred to the standard GC-FID method for exact CBE quantification. In the study, also some challenges offered by SFC-MS have been addressed. Graphical abstract: [Figure not available: see fulltext.] © 2022, Springer-Verlag GmbH Germany, part of Springer Nature.
Název v anglickém jazyce
Supercritical fluid chromatography coupled to high-resolution tandem mass spectrometry: an innovative one-run method for the comprehensive assessment of chocolate quality and authenticity
Popis výsledku anglicky
To assess chocolate quality and authenticity comprehensively, a combination of various analytical procedures is involved, thereby making the process time-consuming and costly. Thus, we investigated the potential of ultra-high performance supercritical fluid chromatography coupled to quadrupole-time of flight mass spectrometry (UHPSFC-QTOF-MS) as an alternative to “classic” methods. By combining hexane and aqueous extracts from sequential extraction, a single 8-min analytical run enabled us (i) to determine cocoa butter equivalents (CBEs) and milk fat content based on the detection of selected triacylglycerols, (ii) to calculate dry non-fat cocoa solids based on determined theobromine and caffeine content, and (iii) to profile contained sugars. To obtain the most comprehensive information about sample composition, the MS method comprised a full MS scan for non-target screening and several time-scheduled targeted MS/MS functions (“parallel reaction monitoring”) optimized according to the possible concentration ranges of the analytes. For 40 different chocolate samples, our results and those obtained by using standard methods (LC-UV for non-fat cocoa solids, and GC-FID for CBEs) were in good agreement. Compared to the conventional approach for chocolate quality and authenticity control, the presented SFC-MS method is a fast, cost-effective, and efficient alternative, and only samples suspicious for the presence of CBE should be referred to the standard GC-FID method for exact CBE quantification. In the study, also some challenges offered by SFC-MS have been addressed. Graphical abstract: [Figure not available: see fulltext.] © 2022, Springer-Verlag GmbH Germany, part of Springer Nature.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/LM2018100" target="_blank" >LM2018100: Infrastruktura pro propagaci metrologie v potravinářství a výživě v České republice</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical and Bioanalytical Chemistry
ISSN
1618-2642
e-ISSN
1618-2650
Svazek periodika
414
Číslo periodika v rámci svazku
23
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
16
Strana od-do
6825-6840
Kód UT WoS článku
000840608600002
EID výsledku v databázi Scopus
2-s2.0-85136963389