Quantification of copper and zinc species fractions in legume seeds extracts by SEC/ICP-MS: validation and uncertainty estimation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F02%3A00007187" target="_blank" >RIV/60461373:22340/02:00007187 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60461373:22330/02:00007187
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Quantification of copper and zinc species fractions in legume seeds extracts by SEC/ICP-MS: validation and uncertainty estimation
Popis výsledku v původním jazyce
Fractions of Cu and Zn species in legume samples (common white bean, pea, chick pea and lentil seeds and defatted soybean flour) were analyzed by on-line hyphenation of size exclusion chromatography and inductively coupled plasma-mass spectrometry. Samples were extracted by 0.02 mol/L Tris-HCl buffer solution, pH = 7.5. The extraction efficiency lay in the region 60 - 90 % and 60 - 80 % for Cu and Zn respectively. Quantification of elements in the individual chromatographic fractions was carried out byisotope dilution (ID) and external calibration (EC) techniques. For ID analysis the chromatographic effluent was mixed with the flow of 65Cu and 68Zn isotope enriched solution and the isotope ratio values 63Cu/65Cu and (64Zn+66Zn)/68Zn were measured. Inthe case of EC technique calibration solutions of elements were injected to the flow of mobile phase by the second injector. Prior entering detector the effluent was mixed with the flow of internal standard solution (In, 50 g/L). Both met
Název v anglickém jazyce
Quantification of copper and zinc species fractions in legume seeds extracts by SEC/ICP-MS: validation and uncertainty estimation
Popis výsledku anglicky
Fractions of Cu and Zn species in legume samples (common white bean, pea, chick pea and lentil seeds and defatted soybean flour) were analyzed by on-line hyphenation of size exclusion chromatography and inductively coupled plasma-mass spectrometry. Samples were extracted by 0.02 mol/L Tris-HCl buffer solution, pH = 7.5. The extraction efficiency lay in the region 60 - 90 % and 60 - 80 % for Cu and Zn respectively. Quantification of elements in the individual chromatographic fractions was carried out byisotope dilution (ID) and external calibration (EC) techniques. For ID analysis the chromatographic effluent was mixed with the flow of 65Cu and 68Zn isotope enriched solution and the isotope ratio values 63Cu/65Cu and (64Zn+66Zn)/68Zn were measured. Inthe case of EC technique calibration solutions of elements were injected to the flow of mobile phase by the second injector. Prior entering detector the effluent was mixed with the flow of internal standard solution (In, 50 g/L). Both met
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA525%2F00%2F0581" target="_blank" >GA525/00/0581: Speciační analýza stopových prvků v potravinách</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Talanta
ISSN
0039-9140
e-ISSN
—
Svazek periodika
57
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
12
Strana od-do
1133-1142
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—