Application of size exclusion chromatography - inductively coupled plasma - mass spectrometry for fractionation of element species in seeds of legumes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F02%3A00007174" target="_blank" >RIV/60461373:22340/02:00007174 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60461373:22330/02:00007174
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Application of size exclusion chromatography - inductively coupled plasma - mass spectrometry for fractionation of element species in seeds of legumes
Popis výsledku v původním jazyce
Fractionation of soluble species of P, Mn, Fe, Co, Ni, Cu, Zn, Se and Mo in pea and lentil seeds was made by on-line hyphenation of SEC and ICP-MS. Seed samples were extracted by 0.02 mol l-1 Tris-HCl buffer solution, pH=7.5. SEC was performed on Superdex 75 and Superdex Peptide columns (300 10 mm) with the same buffer solution as the mobile phase. Monitoring of oxide ion 47(PO)+ was used for detection of phosphorus compounds. Other elements were detected as ions of 55Mn, 57Fe, 59Co, 62Ni, 65Cu, 66Zn, 82Se and 95Mo nuclides. Elements in individual elution zones were quantified using external calibration. Complete chromatographic recoveries of elements were found in cases of phosphorus, nickel and copper. Substantial parts of manganese and zinc, as wellas traces of cobalt, selenium and molybdenum are retained on the column. Injection of EDTA solution removes these elements from the column. Chromatographic profiles of pea and lentil samples are very similar for all elements except Mo. Ma
Název v anglickém jazyce
Application of size exclusion chromatography - inductively coupled plasma - mass spectrometry for fractionation of element species in seeds of legumes
Popis výsledku anglicky
Fractionation of soluble species of P, Mn, Fe, Co, Ni, Cu, Zn, Se and Mo in pea and lentil seeds was made by on-line hyphenation of SEC and ICP-MS. Seed samples were extracted by 0.02 mol l-1 Tris-HCl buffer solution, pH=7.5. SEC was performed on Superdex 75 and Superdex Peptide columns (300 10 mm) with the same buffer solution as the mobile phase. Monitoring of oxide ion 47(PO)+ was used for detection of phosphorus compounds. Other elements were detected as ions of 55Mn, 57Fe, 59Co, 62Ni, 65Cu, 66Zn, 82Se and 95Mo nuclides. Elements in individual elution zones were quantified using external calibration. Complete chromatographic recoveries of elements were found in cases of phosphorus, nickel and copper. Substantial parts of manganese and zinc, as wellas traces of cobalt, selenium and molybdenum are retained on the column. Injection of EDTA solution removes these elements from the column. Chromatographic profiles of pea and lentil samples are very similar for all elements except Mo. Ma
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA525%2F00%2F0581" target="_blank" >GA525/00/0581: Speciační analýza stopových prvků v potravinách</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography B
ISSN
1570-0232
e-ISSN
—
Svazek periodika
778
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
9
Strana od-do
179-187
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—