Analýza reakčně-transportních procesů v mikrofluidních systémech for detekci IgG
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F05%3A00014544" target="_blank" >RIV/60461373:22340/05:00014544 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of reaction-transport phenomena in a Microfluidic System for Detection of IgG
Popis výsledku v původním jazyce
A spatially two-dimensional mathematical model of micro-fluidic biosensor for immunological determination of human immunoglobulin G (IgG) with the use of Protein A (PA) immobilized on the internal walls of a micro-channel is presented. Incubation phase (formation of the immobile PA-IgG complex) of the immunoassay has been studied. It was found that the surface heterogeneities could form complex velocity fields at the location of the adsorption zone: either an intensive flow at the micro-channel walls orthe nozzle-like flow. Generally, the local acceleration of the flow causes the decrease of the mass-transfer resistance. Further, imposed electric field of a proper orientation was able to shorten the incubation phase to 600 s, assuming the micro-channel device with the diameter of 100 mum and the chosen reaction kinetics.
Název v anglickém jazyce
Analysis of reaction-transport phenomena in a Microfluidic System for Detection of IgG
Popis výsledku anglicky
A spatially two-dimensional mathematical model of micro-fluidic biosensor for immunological determination of human immunoglobulin G (IgG) with the use of Protein A (PA) immobilized on the internal walls of a micro-channel is presented. Incubation phase (formation of the immobile PA-IgG complex) of the immunoassay has been studied. It was found that the surface heterogeneities could form complex velocity fields at the location of the adsorption zone: either an intensive flow at the micro-channel walls orthe nozzle-like flow. Generally, the local acceleration of the flow causes the decrease of the mass-transfer resistance. Further, imposed electric field of a proper orientation was able to shorten the incubation phase to 600 s, assuming the micro-channel device with the diameter of 100 mum and the chosen reaction kinetics.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GP104%2F03%2FD006" target="_blank" >GP104/03/D006: Studium mikroreaktorů pro bioinženýrské aplikace</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemical Papers
ISSN
0366-6352
e-ISSN
—
Svazek periodika
59
Číslo periodika v rámci svazku
6a
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
7
Strana od-do
434-440
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—