A robust approach to using of the redundant information in the temperature calibration
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F13%3A43895117" target="_blank" >RIV/60461373:22340/13:43895117 - isvavai.cz</a>
Výsledek na webu
<a href="http://proceedings.aip.org/resource/2/apcpcs/1552/1/498_1" target="_blank" >http://proceedings.aip.org/resource/2/apcpcs/1552/1/498_1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.4819591" target="_blank" >10.1063/1.4819591</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A robust approach to using of the redundant information in the temperature calibration
Popis výsledku v původním jazyce
In the calibration laboratories are used standard procedures for calculating of the calibration model coefficients based on well described standards (EN 60751, ITS-90, EN 60584, etc.). In practice, sensors are mostly calibrated in more points and redundant information is used as a validation of the model. This paper will present the influence of including all measured points with respect to their uncertainties to the measured models using standard weighted least square methods. A special case with regards of the different level of the uncertainty of the measured points in case of the robust approach will be discussed. This will go to the different minimization criteria and different uncertainty propagation methodology. This approach also will eliminateof the influence of the outline measurements in the calibration. In practical part will be three cases of this approach presented, namely industrial calibration according to the standard EN 60751, SPRT according to the ITS-90 and thermoc
Název v anglickém jazyce
A robust approach to using of the redundant information in the temperature calibration
Popis výsledku anglicky
In the calibration laboratories are used standard procedures for calculating of the calibration model coefficients based on well described standards (EN 60751, ITS-90, EN 60584, etc.). In practice, sensors are mostly calibrated in more points and redundant information is used as a validation of the model. This paper will present the influence of including all measured points with respect to their uncertainties to the measured models using standard weighted least square methods. A special case with regards of the different level of the uncertainty of the measured points in case of the robust approach will be discussed. This will go to the different minimization criteria and different uncertainty propagation methodology. This approach also will eliminateof the influence of the outline measurements in the calibration. In practical part will be three cases of this approach presented, namely industrial calibration according to the standard EN 60751, SPRT according to the ITS-90 and thermoc
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
AIP Conference Proceedings
ISBN
978-0-7354-1178-4
ISSN
0094-243X
e-ISSN
—
Počet stran výsledku
6
Strana od-do
498-503
Název nakladatele
American Institute of Physics
Místo vydání
Melville
Místo konání akce
Los Angeles, California
Datum konání akce
19. 3. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—