Anterior interbody fusion of the cervical spine with Zero-P spacer: prospective comparative study-clinical and radiological results at a minimum 2 years after surgery.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61383082%3A_____%2F13%3A0016" target="_blank" >RIV/61383082:_____/13:0016 - isvavai.cz</a>
Výsledek na webu
<a href="http://journals.lww.com/spinejournal/toc/2013/06010" target="_blank" >http://journals.lww.com/spinejournal/toc/2013/06010</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1097/BRS.0b013e3182913400" target="_blank" >10.1097/BRS.0b013e3182913400</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Anterior interbody fusion of the cervical spine with Zero-P spacer: prospective comparative study-clinical and radiological results at a minimum 2 years after surgery.
Popis výsledku v původním jazyce
There are basically 2 ways to provide interbody fusion in the degenerative cervicalspine; the first is by way of an unanchored "stand-alone" bone graft or cage, and the second is with bone graft or a cage anchored with a plate. Both concepts have their own benefits as well as potential drawbacks. Low-profile angle-stable spacer Zero-P is an implant that can potentially limit the drawbacks of both these procedures. METHODS.: Prospective study collecting clinical and radiological data of 77 patients undergoing anterior cervical interbody fusion of 1 or 2 motion segments from C3-C7 was performed. Zero-P spacer was used in 44 patients (55 segments) and in 33 cases (41 segments), stabilization was done using interbody spacer and dynamic anterior cervical plate. Patients were followed a minimum of 2 years after surgery.
Název v anglickém jazyce
Anterior interbody fusion of the cervical spine with Zero-P spacer: prospective comparative study-clinical and radiological results at a minimum 2 years after surgery.
Popis výsledku anglicky
There are basically 2 ways to provide interbody fusion in the degenerative cervicalspine; the first is by way of an unanchored "stand-alone" bone graft or cage, and the second is with bone graft or a cage anchored with a plate. Both concepts have their own benefits as well as potential drawbacks. Low-profile angle-stable spacer Zero-P is an implant that can potentially limit the drawbacks of both these procedures. METHODS.: Prospective study collecting clinical and radiological data of 77 patients undergoing anterior cervical interbody fusion of 1 or 2 motion segments from C3-C7 was performed. Zero-P spacer was used in 44 patients (55 segments) and in 33 cases (41 segments), stabilization was done using interbody spacer and dynamic anterior cervical plate. Patients were followed a minimum of 2 years after surgery.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FH - Neurologie, neurochirurgie, neurovědy
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Spine
ISSN
0362-2436
e-ISSN
—
Svazek periodika
38
Číslo periodika v rámci svazku
13
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
"E792"-"E797"
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—