Průběžná měření celkové vody v těle a tělesné skladby u zdravých dobrovolníků pomocí přímého měření deuteria v dechu a dalších metod
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F05%3A00021163" target="_blank" >RIV/61388955:_____/05:00021163 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Longitudinal measurements of total body water and body composition in healthy volunteers by online breath deuterium measurement and other near-subject methods
Popis výsledku v původním jazyce
Rapid quantification of breath deuterium abundance by flowing afterglow mass spectrometry (FA-MS) enables accurate measurement of total body water (TBW), which combined with other techniques such as bioelectrical impedance analysis (BIA) and anthropometrics enables near-subject assessment of body composition. This study assessed the comparative reproducibility and inter-relationship of these methods in healthy subjects over 12 months. Detailed bedside composition was performed in 22 subjects, (10 male)aged 28?79 with body mass index (BMI) ranging from 21?38 at baseline and again at one year. Techniques included FA-MS deuterium dilution, BIA, skin-fold thickness (SFT) and soft tissue ultrasound measurement of fat and muscle depth. Short-term reproducibility for each method was established. Within and between technique comparisons of measurement were made from Pearson?s linear regression, coefficient of variation (CV) and Bland-Altman analysis.
Název v anglickém jazyce
Longitudinal measurements of total body water and body composition in healthy volunteers by online breath deuterium measurement and other near-subject methods
Popis výsledku anglicky
Rapid quantification of breath deuterium abundance by flowing afterglow mass spectrometry (FA-MS) enables accurate measurement of total body water (TBW), which combined with other techniques such as bioelectrical impedance analysis (BIA) and anthropometrics enables near-subject assessment of body composition. This study assessed the comparative reproducibility and inter-relationship of these methods in healthy subjects over 12 months. Detailed bedside composition was performed in 22 subjects, (10 male)aged 28?79 with body mass index (BMI) ranging from 21?38 at baseline and again at one year. Techniques included FA-MS deuterium dilution, BIA, skin-fold thickness (SFT) and soft tissue ultrasound measurement of fat and muscle depth. Short-term reproducibility for each method was established. Within and between technique comparisons of measurement were made from Pearson?s linear regression, coefficient of variation (CV) and Bland-Altman analysis.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA203%2F00%2F0632" target="_blank" >GA203/00/0632: Chemie iontů v plynné fázi a ve srážkách s povrchy</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Body Composition Research
ISSN
1479-456X
e-ISSN
—
Svazek periodika
2
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
99-106
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—