Kvantitativní stanovení stopových koncentrací potenciálních biomarkerů rakoviny formaldehydu, acetaldehydu a propanolu v dechu pomocí SIFT-MS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F08%3A00314987" target="_blank" >RIV/61388955:_____/08:00314987 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Quantification of trace levels of the potential cancer biomarkers formaldehyde, acetaldehyde and propanol in breath by SIFT-MS
Popis výsledku v původním jazyce
The sensitivity of selected ion flow tube mass spectrometry, SIFT-MS, has been increased such that it is now possible to detect metabolites present at a part-per-billion, ppb, level in single breath exhalations. However, to utilize this improved sensitivity, the overlaps (coincidences) of those ions resulting from interfering reactions of impurity precursor ions with some breath metabolites present at higher concentrations with the analytical product ions characteristic of particular metabolites must beaccounted for. In this paper, the full reaction schemes are presented for SIFT-MS analyses of three volatile potential cancer biomarkers in exhaled breath, namely formaldehyde, HCHO, acetaldehyde, CH3CHO and 2-propanol, CH3CH(OH)CH3, which identify boththe characteristic SIFT-MS product ions for these compounds and the interfering ions at the same mass-to-charge, m/z, values.
Název v anglickém jazyce
Quantification of trace levels of the potential cancer biomarkers formaldehyde, acetaldehyde and propanol in breath by SIFT-MS
Popis výsledku anglicky
The sensitivity of selected ion flow tube mass spectrometry, SIFT-MS, has been increased such that it is now possible to detect metabolites present at a part-per-billion, ppb, level in single breath exhalations. However, to utilize this improved sensitivity, the overlaps (coincidences) of those ions resulting from interfering reactions of impurity precursor ions with some breath metabolites present at higher concentrations with the analytical product ions characteristic of particular metabolites must beaccounted for. In this paper, the full reaction schemes are presented for SIFT-MS analyses of three volatile potential cancer biomarkers in exhaled breath, namely formaldehyde, HCHO, acetaldehyde, CH3CHO and 2-propanol, CH3CH(OH)CH3, which identify boththe characteristic SIFT-MS product ions for these compounds and the interfering ions at the same mass-to-charge, m/z, values.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Breath Research
ISSN
1752-7155
e-ISSN
—
Svazek periodika
2
Číslo periodika v rámci svazku
-
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—