Electrochemical Biosensors Based on Enzymatic Reactors Filled by Various Types of Silica and Amalgam Powders for Measurements in Flow Systems
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F16%3A00467340" target="_blank" >RIV/61388955:_____/16:00467340 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11310/16:10336936
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elan.201600273" target="_blank" >http://dx.doi.org/10.1002/elan.201600273</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201600273" target="_blank" >10.1002/elan.201600273</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrochemical Biosensors Based on Enzymatic Reactors Filled by Various Types of Silica and Amalgam Powders for Measurements in Flow Systems
Popis výsledku v původním jazyce
Two enzymatic biosensors with amalgam powder reactors and twelve enzymatic biosensors with various silica powder reactors were fabricated and tested in this work. The enzymatic reactors based on silver amalgam powder provide high sensitivity and they are convenient for faster flow rates. Experiments with six silica materials showed that mesoporous silica SBA-15 was the best one in terms of covering by enzymes, sensitivity and lifetime of biosensors. The current response of the SBA15-glucose oxidase (GOx) sensor started to decrease only after 200 day testing and after 406 days the peak current was still 35.9 % of the initial value. The used amalgam tubular detector in a flow system allowed working at highly negative potentials, which significantly increased the sensitivity of determinations. Statistical results of parallel measurement of model solutions with the fabricated biosensors show their high accuracy (RSD=0.28–1.81 %) and sensitivity (6.2–14.3 µmol L1). The proposed SBA15-GOx biosensor was successfully used for determination of glucose in commercial honey.
Název v anglickém jazyce
Electrochemical Biosensors Based on Enzymatic Reactors Filled by Various Types of Silica and Amalgam Powders for Measurements in Flow Systems
Popis výsledku anglicky
Two enzymatic biosensors with amalgam powder reactors and twelve enzymatic biosensors with various silica powder reactors were fabricated and tested in this work. The enzymatic reactors based on silver amalgam powder provide high sensitivity and they are convenient for faster flow rates. Experiments with six silica materials showed that mesoporous silica SBA-15 was the best one in terms of covering by enzymes, sensitivity and lifetime of biosensors. The current response of the SBA15-glucose oxidase (GOx) sensor started to decrease only after 200 day testing and after 406 days the peak current was still 35.9 % of the initial value. The used amalgam tubular detector in a flow system allowed working at highly negative potentials, which significantly increased the sensitivity of determinations. Statistical results of parallel measurement of model solutions with the fabricated biosensors show their high accuracy (RSD=0.28–1.81 %) and sensitivity (6.2–14.3 µmol L1). The proposed SBA15-GOx biosensor was successfully used for determination of glucose in commercial honey.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA15-03139S" target="_blank" >GA15-03139S: Nové elektroforetické přístupy pro studium obezity a diabetu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
28
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
11
Strana od-do
3028-3038
Kód UT WoS článku
000392824200017
EID výsledku v databázi Scopus
2-s2.0-85003422157