All-diamond functional surface micro-electrode arrays for brain-slice neural analysis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F17%3A00465775" target="_blank" >RIV/61388955:_____/17:00465775 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/pssa.201532347" target="_blank" >http://dx.doi.org/10.1002/pssa.201532347</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/pssa.201532347" target="_blank" >10.1002/pssa.201532347</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
All-diamond functional surface micro-electrode arrays for brain-slice neural analysis
Popis výsledku v původním jazyce
Diamond-based microelectrode arrays were fabricated by using nanocrystalline diamond as an insulating layer and conductive boron-doped in order to used them for analysis of brain cortical slices. MEA surface is solely composed of diamond, exposed to the cells. The impedance measurements showed negligible cross-talk between neighbouring diamond microelectrodes. Local field potentials related to neural signals were then successfully recorded from pharmacologically disinhibited rat cortical tissue slices, mechanically coupled on the surface of the MEA. The background signal level of the diamond MEAs was found to be lower than commercial Pt-based MEAs, under identical measurement conditions.
Název v anglickém jazyce
All-diamond functional surface micro-electrode arrays for brain-slice neural analysis
Popis výsledku anglicky
Diamond-based microelectrode arrays were fabricated by using nanocrystalline diamond as an insulating layer and conductive boron-doped in order to used them for analysis of brain cortical slices. MEA surface is solely composed of diamond, exposed to the cells. The impedance measurements showed negligible cross-talk between neighbouring diamond microelectrodes. Local field potentials related to neural signals were then successfully recorded from pharmacologically disinhibited rat cortical tissue slices, mechanically coupled on the surface of the MEA. The background signal level of the diamond MEAs was found to be lower than commercial Pt-based MEAs, under identical measurement conditions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Návaznosti výsledku
Projekt
<a href="/cs/project/GA13-31783S" target="_blank" >GA13-31783S: Studium procesu mezifázového přenosu náboje na borem a fosforem dopovaném diamantu v kontaktu s roztokem elektrolytu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physica Status Solidi. A
ISSN
1862-6300
e-ISSN
—
Svazek periodika
214
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
000395007800027
EID výsledku v databázi Scopus
2-s2.0-85002682947