Voltammetric Determination of Tumor Biomarkers using Flow Injection Analysis with Amperometric Detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F17%3A00479846" target="_blank" >RIV/61388955:_____/17:00479846 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11310/17:10371590
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric Determination of Tumor Biomarkers using Flow Injection Analysis with Amperometric Detection
Popis výsledku v původním jazyce
Three tumor biomarkers (homovanillic acid, vanillylmandelic acid,nand 5-hydroxyindole-3-acetic acid) have been determined by flowninjection analysis with amperometric detection at screen-printedncarbon electrodes in optimum medium of Britton-Robinson buffern(0.04 mol l-1, pH = 2.0). Dependences of the peaks current on thenconcentration of biomarkers were linear in the tested concentrationnregion from 0.05 to 100 mu mol l-1, with the limits of detection ofn0.065 mu mol l-1 for homovanillic acid, 0.053 mu mol l-1 for vanillylmandelicnacid, and 0.033 mu mol l-1 for 5-hydroxyindole-3-acetic acid (calculatednfrom heights), and 0.024 mu mol 1-1 for homovanillic acid,n0.020 mu mol l-1 forvanillylmandelic acid, and 0.012 mu mol l-1 for 5-hydroxyindole-3-acetic acid (calculated from areas), respectively.
Název v anglickém jazyce
Voltammetric Determination of Tumor Biomarkers using Flow Injection Analysis with Amperometric Detection
Popis výsledku anglicky
Three tumor biomarkers (homovanillic acid, vanillylmandelic acid,nand 5-hydroxyindole-3-acetic acid) have been determined by flowninjection analysis with amperometric detection at screen-printedncarbon electrodes in optimum medium of Britton-Robinson buffern(0.04 mol l-1, pH = 2.0). Dependences of the peaks current on thenconcentration of biomarkers were linear in the tested concentrationnregion from 0.05 to 100 mu mol l-1, with the limits of detection ofn0.065 mu mol l-1 for homovanillic acid, 0.053 mu mol l-1 for vanillylmandelicnacid, and 0.033 mu mol l-1 for 5-hydroxyindole-3-acetic acid (calculatednfrom heights), and 0.024 mu mol 1-1 for homovanillic acid,n0.020 mu mol l-1 forvanillylmandelic acid, and 0.012 mu mol l-1 for 5-hydroxyindole-3-acetic acid (calculated from areas), respectively.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 13th International Students Conference ”Modern Analytical Chemistry”
ISBN
978-80-7444-052-6
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
7-11
Název nakladatele
Charles University in Prague, Faculty of Science
Místo vydání
Prague
Místo konání akce
Prague
Datum konání akce
21. 9. 2017
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—