Generalized polymer effective charge measurement by capillary isotachophoresis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388963%3A_____%2F14%3A00435675" target="_blank" >RIV/61388963:_____/14:00435675 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.chroma.2014.10.025" target="_blank" >http://dx.doi.org/10.1016/j.chroma.2014.10.025</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2014.10.025" target="_blank" >10.1016/j.chroma.2014.10.025</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Generalized polymer effective charge measurement by capillary isotachophoresis
Popis výsledku v původním jazyce
In this work, we have generalized the use of capillary isotachophoresis as a universal method for determination of effective charge of anionic and cationic (co)polymers on ordinary capillary electrophoresis instruments. This method is applicable to a broad range of strong or weak polyelectrolytes with good repeatability. Experimental parameters (components and concentrations of leading and terminating electrolytes, capillary diameters, constant electric current intensity) were optimized for implementation in 100 mu m i.d. capillaries for both polyanions and polycations. Determined values of polymer effective charge were in a very good agreement with those obtained by capillary electrophoresis with indirect UV detection. Uncertainty of the effective charge measurement using isotachophoresis was addressed and estimated to be similar to 5-10% for solutes with mobilities in the 20-50 x 10(-9) m(2) V-1 s(-1) range.
Název v anglickém jazyce
Generalized polymer effective charge measurement by capillary isotachophoresis
Popis výsledku anglicky
In this work, we have generalized the use of capillary isotachophoresis as a universal method for determination of effective charge of anionic and cationic (co)polymers on ordinary capillary electrophoresis instruments. This method is applicable to a broad range of strong or weak polyelectrolytes with good repeatability. Experimental parameters (components and concentrations of leading and terminating electrolytes, capillary diameters, constant electric current intensity) were optimized for implementation in 100 mu m i.d. capillaries for both polyanions and polycations. Determined values of polymer effective charge were in a very good agreement with those obtained by capillary electrophoresis with indirect UV detection. Uncertainty of the effective charge measurement using isotachophoresis was addressed and estimated to be similar to 5-10% for solutes with mobilities in the 20-50 x 10(-9) m(2) V-1 s(-1) range.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Svazek periodika
1370
Číslo periodika v rámci svazku
Nov 28
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
255-262
Kód UT WoS článku
000345724800029