Coloring of radiation damages in ion-implanted poly(aryl ether ether ketone): LiCl uptake and thermal desorption.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F02%3A49020016" target="_blank" >RIV/61389005:_____/02:49020016 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Coloring of radiation damages in ion-implanted poly(aryl ether ether ketone): LiCl uptake and thermal desorption.
Popis výsledku v původním jazyce
Poly(aryl ether ether ketone) (PEEK) films irradiated with 2 MeV O+ and Ar+ ions to fluences in the range 10(11)-10(13) cm(-2) were treated with 5 mol/L LiCl aqueous solution at 100degreesC for 1 h. After removal of excessive, weakly bound LiCl the samples were annealed at temperatures from 50 to 250degreesC for 1 h to check the mobility of the incorporated LiCl. The amount of incorporated LiCl and its depth profile were determined using the neutron depth-profiling (NDP) technique, which makes use of the Li-6(n(th), He-4) H-3 nuclear reaction. Up to the maximum annealing temperature no significant escape of the LiCl was observed. With increasing annealing temperature, a gradual migration of LiCl dopant toward the sample surface was observed on the irradiated PEEK samples.
Název v anglickém jazyce
Coloring of radiation damages in ion-implanted poly(aryl ether ether ketone): LiCl uptake and thermal desorption.
Popis výsledku anglicky
Poly(aryl ether ether ketone) (PEEK) films irradiated with 2 MeV O+ and Ar+ ions to fluences in the range 10(11)-10(13) cm(-2) were treated with 5 mol/L LiCl aqueous solution at 100degreesC for 1 h. After removal of excessive, weakly bound LiCl the samples were annealed at temperatures from 50 to 250degreesC for 1 h to check the mobility of the incorporated LiCl. The amount of incorporated LiCl and its depth profile were determined using the neutron depth-profiling (NDP) technique, which makes use of the Li-6(n(th), He-4) H-3 nuclear reaction. Up to the maximum annealing temperature no significant escape of the LiCl was observed. With increasing annealing temperature, a gradual migration of LiCl dopant toward the sample surface was observed on the irradiated PEEK samples.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Applied Polymer Science
ISSN
0021-8995
e-ISSN
—
Svazek periodika
83
Číslo periodika v rámci svazku
N/A
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
2780-2784
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—