Prostorové rozlišení Medipix-2 jako neutronového pixlového detektoru
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F05%3A00031535" target="_blank" >RIV/61389005:_____/05:00031535 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Spatial resolution of Medipix-2 device as neutron pixel detector
Popis výsledku v původním jazyce
Nowadays, promising digital active pixel detector systems are available and make real time imaging with high sensitivity and broad dynamic range possible. The hybrid silicon pixel detector device Medipix-2 was originally designed for single X-ray photondetection. The device consists of a sensor chip with 256 x 256 square pixels of 55 ?m size. The detector can be adapted for neutron detection by deposition of a converter layer to its surface. Thermal neutrons are converted in the layer into the secondary radiation which can be subsequently detected by the pixel detector. Different types of converter materials were examined with the aim to reach maximal spatial resolution at reasonable detection efficiency. The results demonstrate superior properties ofthe Medipix-2-based thermal neutron imager with a 6LiF converter in terms of spatial resolution, signal-to-noise ratio, linearity and dynamic range.
Název v anglickém jazyce
Spatial resolution of Medipix-2 device as neutron pixel detector
Popis výsledku anglicky
Nowadays, promising digital active pixel detector systems are available and make real time imaging with high sensitivity and broad dynamic range possible. The hybrid silicon pixel detector device Medipix-2 was originally designed for single X-ray photondetection. The device consists of a sensor chip with 256 x 256 square pixels of 55 ?m size. The detector can be adapted for neutron detection by deposition of a converter layer to its surface. Thermal neutrons are converted in the layer into the secondary radiation which can be subsequently detected by the pixel detector. Different types of converter materials were examined with the aim to reach maximal spatial resolution at reasonable detection efficiency. The results demonstrate superior properties ofthe Medipix-2-based thermal neutron imager with a 6LiF converter in terms of spatial resolution, signal-to-noise ratio, linearity and dynamic range.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1P04LA211" target="_blank" >1P04LA211: Spolupráce ČR s CERN</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research. A
ISSN
0168-9002
e-ISSN
—
Svazek periodika
546
Číslo periodika v rámci svazku
-
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
164-169
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—