Prostorové rozlišení zařízení Medipix-2 jako neutronového pixelového detektoru
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F05%3A15118622" target="_blank" >RIV/68407700:21670/05:15118622 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21670/05:15118621
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Spatial Resolution of Medipix-2 as Neutron Pixel Detector
Popis výsledku v původním jazyce
Nowadays promising digital pixel detector systems are available and make possible real time imaging with high sensitivity and broad dynamic range. The hybrid silicon pixel detector device Medipix-2 (256 x 256 square pixels of 55 m size) was originally designed for single X-ray photon detection. The detector can be adapted for neutron detection by deposition of a converter layer to its surface. Thermal neutrons are converted into the secondary radiation detectable by the pixel detector. Differenttypes of converter materials were examined with the aim to reach maximal spatial resolution at reasonable detection efficiency. The results demonstrate superior properties of the Medipix-2 based thermal neutron imager in terms of spatial resolution, signal-to-noise ratio, linearity and dynamic range. Several images of real objects demonstrating the capabilities of the device are presented.
Název v anglickém jazyce
Spatial Resolution of Medipix-2 as Neutron Pixel Detector
Popis výsledku anglicky
Nowadays promising digital pixel detector systems are available and make possible real time imaging with high sensitivity and broad dynamic range. The hybrid silicon pixel detector device Medipix-2 (256 x 256 square pixels of 55 m size) was originally designed for single X-ray photon detection. The detector can be adapted for neutron detection by deposition of a converter layer to its surface. Thermal neutrons are converted into the secondary radiation detectable by the pixel detector. Differenttypes of converter materials were examined with the aim to reach maximal spatial resolution at reasonable detection efficiency. The results demonstrate superior properties of the Medipix-2 based thermal neutron imager in terms of spatial resolution, signal-to-noise ratio, linearity and dynamic range. Several images of real objects demonstrating the capabilities of the device are presented.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
ISSN
0168-9002
e-ISSN
—
Svazek periodika
546
Číslo periodika v rámci svazku
1-2
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
164-169
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—