Pixlový detektor vhodný pro detekci pomalých neutronů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F05%3A00031536" target="_blank" >RIV/61389005:_____/05:00031536 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21670/05:15118199 RIV/26722445:_____/05:#0000402
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Performance of a pixel detector suited for slow neutrons
Popis výsledku v původním jazyce
Semiconductor pixel radiation detector systems have recently made significant progress achieving excellent spatial resolution, high sensitivity, wide dynamic range and low noise. The hybrid silicon pixel device of Medipix type developed at CERN was originally designed for position sensitive single X-ray photon detection. We have adapted this device to a position sensitive detector of slow neutrons by covering the detector surface with a 6LiF neutron converter. Neutrons are converted to tritons and alphaparticles which are subsequently detected by the silicon pixel detector. The basic parameters of such a pixel neutron sensitive device were investigated using thermal neutron beams. Tests for neutron imaging applications and comparison with currently used devices for neutron radiography (CCD camera with scintillator, imaging plates) were performed.
Název v anglickém jazyce
Performance of a pixel detector suited for slow neutrons
Popis výsledku anglicky
Semiconductor pixel radiation detector systems have recently made significant progress achieving excellent spatial resolution, high sensitivity, wide dynamic range and low noise. The hybrid silicon pixel device of Medipix type developed at CERN was originally designed for position sensitive single X-ray photon detection. We have adapted this device to a position sensitive detector of slow neutrons by covering the detector surface with a 6LiF neutron converter. Neutrons are converted to tritons and alphaparticles which are subsequently detected by the silicon pixel detector. The basic parameters of such a pixel neutron sensitive device were investigated using thermal neutron beams. Tests for neutron imaging applications and comparison with currently used devices for neutron radiography (CCD camera with scintillator, imaging plates) were performed.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research. A
ISSN
0168-9002
e-ISSN
—
Svazek periodika
542
Číslo periodika v rámci svazku
-
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
283-287
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—