Biophysical simulation tool PARTRAC: Modelling proton beams at therapy-relevant energies
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F19%3A00523897" target="_blank" >RIV/61389005:_____/19:00523897 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1093/rpd/ncz197" target="_blank" >https://doi.org/10.1093/rpd/ncz197</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncz197" target="_blank" >10.1093/rpd/ncz197</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Biophysical simulation tool PARTRAC: Modelling proton beams at therapy-relevant energies
Popis výsledku v původním jazyce
The biophysical simulation tool PARTRAC has been primarily developed to model radiation physics, chemistry and biology on nanometre to micrometre scales. However, the tool can be applied in simulating radiation effects in an event-by-event manner over macroscopic volumes as well. Benchmark simulations are reported showing that PARTRAC does reproduce the macroscopic Bragg peaks of proton beams, although the penetration depths are underestimated by a few per cent for high-energy beams. PARTRAC also quantifies the increase in DNA damage and its complexity along the beam penetration depth. Enhanced biological effectiveness is predicted in particular within distal Bragg peak parts of therapeutic proton beams.
Název v anglickém jazyce
Biophysical simulation tool PARTRAC: Modelling proton beams at therapy-relevant energies
Popis výsledku anglicky
The biophysical simulation tool PARTRAC has been primarily developed to model radiation physics, chemistry and biology on nanometre to micrometre scales. However, the tool can be applied in simulating radiation effects in an event-by-event manner over macroscopic volumes as well. Benchmark simulations are reported showing that PARTRAC does reproduce the macroscopic Bragg peaks of proton beams, although the penetration depths are underestimated by a few per cent for high-energy beams. PARTRAC also quantifies the increase in DNA damage and its complexity along the beam penetration depth. Enhanced biological effectiveness is predicted in particular within distal Bragg peak parts of therapeutic proton beams.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
—
Svazek periodika
186
Číslo periodika v rámci svazku
2-3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
172-175
Kód UT WoS článku
000530582200006
EID výsledku v databázi Scopus
2-s2.0-85082881470