Investigations on graphene oxide for ion beam dosimetry applications
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F20%3A00525528" target="_blank" >RIV/61389005:_____/20:00525528 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1016/j.vacuum.2020.109451" target="_blank" >https://doi.org/10.1016/j.vacuum.2020.109451</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.vacuum.2020.109451" target="_blank" >10.1016/j.vacuum.2020.109451</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Investigations on graphene oxide for ion beam dosimetry applications
Popis výsledku v původním jazyce
The oxygen content in graphene oxide (GO) can be reduced by the ion beam irradiation in high vacuum conditions. The reduction changes the C/O atomic ratio that increases with the absorbed ion dose. Moreover, as the level of reduction increases, the surface flattens and the material becomes denser. At high absorbed doses, greater than about 100 MGy, the material is affected by the high energy deposited with damage radiation effects which make the C/O ratio not proportional to the dose. At low doses, less than about 100 MGy, the C/O atomic ratio shows an optimal linearity with the ion dose and is independent of the ion stopping power, thus assuming the characteristics of a good biocompatible water-tissue equivalent dosimeter.
Název v anglickém jazyce
Investigations on graphene oxide for ion beam dosimetry applications
Popis výsledku anglicky
The oxygen content in graphene oxide (GO) can be reduced by the ion beam irradiation in high vacuum conditions. The reduction changes the C/O atomic ratio that increases with the absorbed ion dose. Moreover, as the level of reduction increases, the surface flattens and the material becomes denser. At high absorbed doses, greater than about 100 MGy, the material is affected by the high energy deposited with damage radiation effects which make the C/O ratio not proportional to the dose. At low doses, less than about 100 MGy, the C/O atomic ratio shows an optimal linearity with the ion dose and is independent of the ion stopping power, thus assuming the characteristics of a good biocompatible water-tissue equivalent dosimeter.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Vacuum
ISSN
0042-207X
e-ISSN
—
Svazek periodika
178
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
109451
Kód UT WoS článku
000541439800024
EID výsledku v databázi Scopus
2-s2.0-85084839611