EasyClick: an improved system for confocal microscopy of live roots with a user-optimized sample holder
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389030%3A_____%2F24%3A00582673" target="_blank" >RIV/61389030:_____/24:00582673 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/23:PU149505 RIV/61989592:15310/24:73625406
Výsledek na webu
<a href="https://doi.org/10.1007/s00425-023-04293-y" target="_blank" >https://doi.org/10.1007/s00425-023-04293-y</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00425-023-04293-y" target="_blank" >10.1007/s00425-023-04293-y</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
EasyClick: an improved system for confocal microscopy of live roots with a user-optimized sample holder
Popis výsledku v původním jazyce
Preparation and mounting of the samples are key factors for successful live cell microscopy. To acquire biologically relevant data, it is necessary to minimize stress and avoid physical damage to plant tissues during the installation of the sample into the microscope. This is challenging, particularly when the whole plant is mounted as the living sample needs to be properly anchored in the microscopic system to obtain high-quality and high-resolution data. Here, we present a user-optimized sample holder EasyClick for live cell inverted confocal microscopic analysis of plant roots with diameters from 0.3 to 0.7 mm. The EasyClick holder was tested on an inverted confocal microscope using germinating plants of several cereals. Nevertheless, it can be directly used on other types of inverted microscopes from various producers and on different plant species. The EasyClick holder effectively restricts root lateral and vertical movements. This greatly improves the conditions for time-lapse microscopy of the samples of interest.
Název v anglickém jazyce
EasyClick: an improved system for confocal microscopy of live roots with a user-optimized sample holder
Popis výsledku anglicky
Preparation and mounting of the samples are key factors for successful live cell microscopy. To acquire biologically relevant data, it is necessary to minimize stress and avoid physical damage to plant tissues during the installation of the sample into the microscope. This is challenging, particularly when the whole plant is mounted as the living sample needs to be properly anchored in the microscopic system to obtain high-quality and high-resolution data. Here, we present a user-optimized sample holder EasyClick for live cell inverted confocal microscopic analysis of plant roots with diameters from 0.3 to 0.7 mm. The EasyClick holder was tested on an inverted confocal microscope using germinating plants of several cereals. Nevertheless, it can be directly used on other types of inverted microscopes from various producers and on different plant species. The EasyClick holder effectively restricts root lateral and vertical movements. This greatly improves the conditions for time-lapse microscopy of the samples of interest.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10601 - Cell biology
Návaznosti výsledku
Projekt
<a href="/cs/project/GA21-02929S" target="_blank" >GA21-02929S: Identifikace a charakterizace imprintovaných genů v průběhu vývoje semen ječmene</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Planta
ISSN
0032-0935
e-ISSN
1432-2048
Svazek periodika
259
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
22
Kód UT WoS článku
001125097100001
EID výsledku v databázi Scopus
2-s2.0-85179685820