Application of Typical Error of Measurement for Accuracy of Measurement of Body Composition in Athletes Using the BIA Method
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61988987%3A17450%2F12%3AA13015ZO" target="_blank" >RIV/61988987:17450/12:A13015ZO - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Application of Typical Error of Measurement for Accuracy of Measurement of Body Composition in Athletes Using the BIA Method
Popis výsledku v původním jazyce
To ensure the interpretation of the measured results during repeated measuring, it is necessary to know the accuracy of measurement of the used method and device. One of the possibilities of expressing this error is to use typical error of measurement. Aim: To determine the actual error of measurement of the monitored body composition parameters when applying the bioelectrical impedance method in soccer players using typical error of measurement. The research included a group of 50 men whose average agewas 20.35 ? 1.25 years; they were soccer players in the U21 age category. The measurement of the monitored parameters was carried out using the Tanita 418 MA device; the accuracy of measurement was determined using typical error of measurement and interclass correlation. The typical error of measurement allows us to determine actual errors of measurement expressed in the used measurement units.
Název v anglickém jazyce
Application of Typical Error of Measurement for Accuracy of Measurement of Body Composition in Athletes Using the BIA Method
Popis výsledku anglicky
To ensure the interpretation of the measured results during repeated measuring, it is necessary to know the accuracy of measurement of the used method and device. One of the possibilities of expressing this error is to use typical error of measurement. Aim: To determine the actual error of measurement of the monitored body composition parameters when applying the bioelectrical impedance method in soccer players using typical error of measurement. The research included a group of 50 men whose average agewas 20.35 ? 1.25 years; they were soccer players in the U21 age category. The measurement of the monitored parameters was carried out using the Tanita 418 MA device; the accuracy of measurement was determined using typical error of measurement and interclass correlation. The typical error of measurement allows us to determine actual errors of measurement expressed in the used measurement units.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
AC - Archeologie, antropologie, etnologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Medicina Sportiva
ISSN
1734-2260
e-ISSN
—
Svazek periodika
4
Číslo periodika v rámci svazku
prosinec
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
5
Strana od-do
150-154
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—